Справочник Пользователя для Lucent Technologies Comcode 108678723
DEFINITY ECS Release 8.2 ATM Installation,
Upgrades, and Administration
Upgrades, and Administration
555-233-124
Issue 1
April 2000
Administering ATM-PNC and ATM-CES
5-31
Administering DEFINITY ECS
5
Field description:
Gain/Loss adjustments
Gain and loss are administrable. Calls between a digital (BRI or DCP) phone
(6400 and 8400 series) and an analog trunk port require adjustments to the
default gain/loss settings to prevent distortion. Use the procedure (
(6400 and 8400 series) and an analog trunk port require adjustments to the
default gain/loss settings to prevent distortion. Use the procedure (
) to
administer digital phones on ATM-PNC DEFINITY ECSs.
NOTE:
Use the following procedure only for Series 6400 or 8400 digital phones.
Algorithm
The name of the cache algorithm (default is lan). Possible values are
none, lan, man, wan, and custom.
none, lan, man, wan, and custom.
When this field is changed to none, lan, man, or wan, the read-only
For
Latency
and
Hold Time
field values change to the following (all other
entries are blank):
Value
For Latency (ms)
Hold Time (ms)
none
0
0
lan
50
36
0
12
man
800
80
50
16
0
8
wan
800
200
200
36
50
16
0
0
When this field is custom, none of the
For Latency
or
Hold Time
field
values change, but the fields change from read-only to read/write. For
example, if you want a slight variation of the wan algorithm, type wan first
to set the above values, then type custom to change the individual
parameters.
example, if you want a slight variation of the wan algorithm, type wan first
to set the above values, then type custom to change the individual
parameters.
Size
The maximum number of entries simultaneously allowed in the cache
(default = 410).
(default = 410).
For Latency
These fields (10) are read-only if the
Algorithm
field is none, lan, man,
or wan, but are read/write if
Algorithm
is custom. Defaults: 36 for the
1st entry, 0 for the second, blank for the last 8 entries.