DEFINITY ECS Release 8.2 ATM Installation,
Upgrades, and Administration  
555-233-124  
Issue 1
April 2000
Administering ATM-PNC and ATM-CES 
5-31
Administering DEFINITY ECS 
5
Field description:
Gain/Loss adjustments 
Gain and loss are administrable. Calls between a digital (BRI or DCP) phone 
(6400 and 8400 series) and an analog trunk port require adjustments to the 
default gain/loss settings to prevent distortion. Use the procedure (
) to 
administer digital phones on ATM-PNC DEFINITY ECSs.
NOTE:
Use the following procedure only for Series 6400 or 8400 digital phones.
Algorithm
The name of the cache algorithm (default is lan).  Possible values are 
nonelanmanwan, and custom.
When this field is changed to nonelanman, or wan, the read-only 
For 
Latency
 and 
Hold Time
 field values change to the following (all other 
entries are blank):
Value
For Latency (ms)
Hold Time (ms)
none
0
0
lan
50
36
0
12
man
800
80
50
16
0
8
wan
800
200
200
36
50
16
0
0
When this field is custom, none of the 
For Latency
 or 
Hold Time
 field 
values change, but the fields change from read-only to read/write.  For 
example, if you want a slight variation of the wan algorithm, type wan first 
to set the above values, then type custom to change the individual 
parameters.
Size
The maximum number of entries simultaneously allowed in the cache 
(default = 410).
For Latency
These fields (10) are read-only if the 
Algorithm
 field is nonelanman
or wan, but are read/write if 
Algorithm
 is custom. Defaults: 36 for the 
1st entry, 0 for the second, blank for the last 8 entries.