DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-74
Add IP Interface Assembly 
6
Connect the Monitor, Keyboard, and Mouse
1. Attach a VGA monitor to the VGA connector of the TN802 IP Interface 
external cable assembly.
2. Attach the keyboard to the KEYBOARD connector of the external cable 
assembly.
3. Attach the mouse to the MOUSE connector of the external cable 
assembly.
4. Plug the monitor into an AC power receptacle and turn it on.
5. If upgrading locally, reboot Windows NT by pressing the recessed reset 
button on the faceplate (see 
) of the TN802B IP Interface until 
the LCD shows a flashing MSHUT *. When the flashing stops and the 
asterisk disappears (about 2 min), it is safe to remove the circuit pack.
6. After the TN802B is shut down, reseat the circuit pack to restart the 
system.
7. Log in using ctrl alt del
Upgrading IP trunks (R7) to H.323 trunks
If there are existing IP trunk connections that you want to upgrade to H.323 trunk 
connections, do the following steps. Otherwise, go to 
To upgrade an existing IP trunk (R7) to an H.323 trunk (R8) requires first getting 
IP information from the existing TN802 before upgrading the TN802 to TN802B.
1. Click on My Computer > Control Panel > Network.
2. Click the Protocols tab.
3. Select TCP/IP Protocol from the list.
4. Click the Properties option in the Network window
.
 Write down the IP 
address, subnet address, and gateway address shown for adaptor [2] 
(see example below).
NOTE:
Do not use the addresses for adapter [1].