Справочник Пользователя для Lucent Technologies 555-233-115
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Fiber Link Administration
A-11
Administer Fiber Links
A
Duplicated Fiber Link Administration.
Screen 6-2.
Fiber Link Administration form (page 1 of 3)
The following fields appear when
Administration of PNC Duplication
is
enabled on the System-Parameters Customer-Options form:
■
Fiber Link #
—
Display-only field. From the command line, enter a 1- to
3-digit number to uniquely identify a switch connection in the system and
its duplicate if appropriate.
its duplicate if appropriate.
■
Is one endpoint remoted via DS1 Converter Complex?
—
Enter yes to
specify that a DS1 converter complex is used to remote one endpoint. If
yes is entered, A-PNC and B-PNC DS1 Converter (DS1CONV) Attributes
must be administered on Pages 2 and 3 (respectively) of the form.
yes is entered, A-PNC and B-PNC DS1 Converter (DS1CONV) Attributes
must be administered on Pages 2 and 3 (respectively) of the form.
■
Board Location
—
Enter the cabinet, carrier, and slot that identifies the
physical location of a circuit pack in the first endpoint of the duplicate fiber
link. Endpoint-1’s duplicate along with Endpoint-2’s duplicate make up the
duplicate fiber link called the B-PNC link.
link. Endpoint-1’s duplicate along with Endpoint-2’s duplicate make up the
duplicate fiber link called the B-PNC link.
■
Board Type
—
Display-only field showing the type of circuit pack in
Endpoint-1. The circuit pack type in Endpoint-1 (A-PNC) and Endpoint-1
(B-PNC) must be the same.
(B-PNC) must be the same.
■
DS1CONV Board Location
—
Enter the cabinet, carrier, and slot that
identifies the physical location of DS1 Converter circuit pack in the first
endpoint of the duplicate fiber link. Endpoint-1’s duplicate along with
Endpoint-2’s duplicate make up the duplicate fiber link called the B-PNC
link.
endpoint of the duplicate fiber link. Endpoint-1’s duplicate along with
Endpoint-2’s duplicate make up the duplicate fiber link called the B-PNC
link.
add fiber-link next
Page 1 of 3
FIBER LINK ADMINISTRATION
Fiber Link #: 1
Is one endpoint remoted via DS1 Converter Complex? yes
Is one endpoint remoted via DS1 Converter Complex? yes
ENDPOINT-1
ENDPOINT-2
(A-PNC) (A-PNC)
Board Location: 01E01
Board Location: 02A01
Board Type: ei
Board Type: ei
DS1CONV Board Location: 01B01
DS1CONV Board Location: 02B01
DS1CONV Board Type: TN574
DS1CONV Board Type: TN574
ENDPOINT-1 ENDPOINT-2
(B-PNC) (B-PNC)
(B-PNC) (B-PNC)
Board Location: 01D01
Board Location: 02A02
Board Type: ei
Board Type: ei
DS1CONV Board Location: 01C01
DS1CONV Board Location: 02C01
DS1CONV Board Type: TN574
DS1CONV Board Type: TN574