Справочник Пользователя для Lucent Technologies 555-233-115
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Upgrading G3rV2, V3, V4 to R8r and Adding Memory
1-7
Upgrade the software and hardware
1
Disable Scheduled Maintenance and Alarm
Origination to INADS
Origination to INADS
1. To prevent scheduled daily maintenance from interfering with the update
or upgrade, type change system-parameters maintenance and press
Enter
.
2. If scheduled maintenance has begun, set the
Stop Time
field to 1 minute
after the current time.
or
If scheduled maintenance has not begun, set the
Start Time
field to a
time after the upgrade is completed. For example, if you start the upgrade
at 8:00 p.m. and the upgrade takes 90 minutes, set the
at 8:00 p.m. and the upgrade takes 90 minutes, set the
Start Time
field
to 21:30.
!
CAUTION:
If you do not disable Alarm Origination, the system may generate
alarms, resulting in unnecessary trouble tickets.
alarms, resulting in unnecessary trouble tickets.
3. Type neither in the
Alarm Origination to OSS Numbers
field and
press
Enter.
NOTE:
For some software loads, set the
Alarm Origination
Activated
field to n and set the
Cleared Alarm Notification
and
Restart Notification
fields to disable or n before
pressing
Enter
.
Reconfigure the Tape (G3rV2, V3 R31.0 and
Earlier)
Earlier)
NOTE:
Do not issue the list configuration software command before
reconfiguring the removable media.
reconfiguring the removable media.
For some software loads, use 3-mem instead of large
If standard reliability:
1. Type configure tape large and press
Enter
to reconfigure the backup
removable media for the 2 TN1650B Memory circuit packs. This command
takes about 1 minute to complete.
takes about 1 minute to complete.