Configuring the RAS with a Web browser
40
Model 2960/2996 RAS User Manual 
3 • Configuring the RAS for operation
Configuring the line settings
1. Click on the 
Line Type
 pop-up menu (see 
 on page 39) and choose from the following options:
– For an E1/PRI line your options will be either dsx1E1(4) or dsx1E1-CRC(5)
– For an E1/R2 line your options will be either dsx1E1-MF(6) or dsx1E1-CRC-MF(7)
2. Click on the 
Line Coding
 pop-up menu (see 
 on page 39) and choose either dsx1AMI(5) or 
dsxHDB3(3). Most installations will use HDB3.
3. Click on the 
Line Build Out
 pop-up menu (see 
 on page 39) and select e1pulse(1).
4. Click on 
Yellow Alarm Format
 pop-up menu (see 
 on page 39) and choose from the following 
options:
– For an E1/PRI line choose linkYellowFormatDL(2)
– For an E1/R2 line choose linkYellowAlarmFormatBit2(1)
5. Click on 
Submit Query
.
At this point, the WAN front panel LEDs will become active. A solid green FRAME light indicator means that 
the RAS has synchronized with the E1 line. 
Note
If you suspect that there is a physical malfunction in the WAN ports, 
you can assemble a loopback connector to test the port (see 
Figure 30. Pinout for loopback to test WAN port