Справочник Пользователя для Pelco VMX300
C1552M-C (7/07)
37
Alternate CM9700 Connection
If you control your CM9700 system with CM9760-MGR software, you can use the RS-232 COM port on the CC1 for the VMX300(-E) connection.
Complete the following steps to connect the VMX300(-E) to the CC1:
Complete the following steps to connect the VMX300(-E) to the CC1:
1. Using a null modem cable (user-supplied), plug one end into one of the RS-232 ports (COM 1 or COM 2) on the VMX300(-E).
2. Plug the other end of the cable into the RS-232 COM 2 port on the CC1.
Figure 35. CM9700 RS-232 Connections
3. After installing system hardware, complete the following configuration steps (refer to the VMX300(-E) Server Configuration Manual for
detailed instructions):
a.
Add the Pelco P driver and the switcher to the VMX300(-E) server configuration, and select Direct Series as the connection type.
b.
In the CM9760-MGR software, change the CC1 RS-232 COM 2 settings to match the VMX300(-E) RS-232 COM port settings: 9600
baud, no parity, 8 data bits, 1 stop bit. Designate the port as a keyboard (equipment number 100).
baud, no parity, 8 data bits, 1 stop bit. Designate the port as a keyboard (equipment number 100).
NOTE: If you use the Pelco ASCII driver in the VMX300(-E) server configuration, some of these settings will change (refer to the VMX300(-E)
Server Configuration Manual for information on when and how to use the ASCII driver).
Server Configuration Manual for information on when and how to use the ASCII driver).
PRINTER COM1
COM2
CM9740-CC1
CM9700-CC1
CM9740-CC1
OR
CM9700-CC1
NULL MODEM CABLE
COM1
COM2
PRINTER LPT1
VGA