Справочник Пользователя для Pelco VMX300

Скачать
Страница из 50
40
C1552M-C (7/07)
SERIAL OUTPUT DEVICE
Connect a serial output device to the VMX300(-E) using either a direct serial connection or an Internet Protocol connection. Refer to Figure 24 on 
page 27 for
 a sample direct serial connection or to Figure 26 on page 28 for a sample Internet Protocol connection.
After installing system hardware, complete the following configuration steps:
1. Add the Serial Output driver and the serial output device to the VMX300(-E) server configuration (refer to the VMX300(-E) Server 
Configuration Manual for instructions).
2. Change the serial output device settings to match the VMX300(-E) COM port: RS-232, 9600 baud, odd parity, 8 data bits, 1 stop bit (refer to 
the appropriate device manual for instructions).
IP-BASED DEVICES
You can connect the following devices to the VMX300(-E) over a network:
DX8000 and DX9000 Series DVRs
PelcoNet MPEG Series transmission systems (NET300 Series, NET350 Series, NET4001A)
NVR300 Series network video recorders 
Matrix switchers (through a PelcoNet transmission system)
Spectra/Esprit camera positioning systems (through a PelcoNet transmission system)
CM9760-ALM and CM9760-REL input/output devices
To connect an IP-based device to a 10/100BaseT network, plug a standard unshielded twisted pair Cat5 cable with RJ-45 connectors into the 
device’s Ethernet port.
Figure 38.  Sample IP-Based Device Connection
NETWORK
Video In
Video Out
Audio Out
Audio In
COM1: RS232/485 10/100 Base-T
Ethernet
Power
100-250VAC50/60Hz 100mA
COM2: RS232