Serial Port Profiles
Power Management Profile
Overview
The Power Management profile applies when there is a Perle Remote Power Switch (RPS) connected 
to the serial port. This profile is used to configure the RPS. See 
 for 
information on how to actively management the RPS.
Functionality
The Power Management profile configures a serial port to communicate with a Remote Power 
Switch’s (RPS) administration port. This allows network access to the RPS and permits access to 
statistics and control of the RPS’s power plugs.
Embedded
When this option is selected, the address of the slave Modbus device is 
embedded in the message header.
Default: Enabled
Remapped
Used for single device/port operation. Older Modbus devices may not include a 
UID in their transmission header. When this option is selected, you can specify 
the UID that will be inserted into the message header for the Modbus slave 
device. This feature supersedes the Broadcast feature.
Default: Disabled
Remap UID
Specify the UID that will be inserted into the message header for the Slave 
Modbus serial device. 
Range: 1-247
Default: 1
Enable SSL/TLS 
using global 
settings
When enabled, Modbus Slave Gateway messages to remote TCP Modbus 
Masters are encrypted via SSL/TLS.
Default: Disabled