Справочник Пользователя для HP (Hewlett-Packard) A.06.10

Скачать
Страница из 100
Ensure the database table DPCELLS is present.
If the tables do not exists, create/recreate them using the
following commands:
newdb
-xml
INSTALL_DIR\newconfig\
Packages\DPCELLS.xml
and
newdb -xml
INSTALL_DIR\newconfig\
Packages\DPTREND.xml
Action
Cell Manager already exists in the Reporter
database!! Error Code: 23000
Error message
A Data Protector Cell Manager is already registered with
ReporterLite, and you cannot use this application to update the
information.
Description
To add the same Data Protector Cell Manager, with different
information, remove the existing information from the database
and then add the new information.
To remove (de-register) a Cell Manager, use the AddCell.exe
application, enter the relevant details and click Remove Cell.
Once the Cell Manager is de-registered, data for reports can no
longer be collected from it.
Action
Gathering data from Data Protector
Once Data Protector Cell Managers are registered to ReporterLite, the utility
DPGather.exe
collects data from them. It is launched automatically when required.
Generating reports
ReporterLite utility Repcrys.exe generates reports. It is launched automatically
when required.
Viewing reports
Use the following link to view generated reports:
ReporterLite integration
80