Листовка для Liebert F277Y800-03

Скачать
Страница из 1
 
Liebert Corporation • 1050 Dearborn Drive • PO Box 29186 • Columbus, OH  43229  
Phone 607-724-2484 • Fax 607-722-8713 • US & Canada 800-288-6169 
EMAIL: info@control-concepts.com • Web Site: www.Liebert.com 
   
      82245 Rev 0
 
 
  
UL 1449 second edition clamping data
Voltage 
L-N 
L-G 
L-L 
N-G 
100-120V 400 400 800 400 
208V  
800 
800 
 
230-277V 800  800  1500 700 
347V 1200 
1000 
2000 
1000 
400-480V   1500 
1500  
600V  
2000 
2000 
 
Liebert Active Tracking Filter System
Technical Specification 
 
Operating Voltage Range ......................................... +/-15% 
 
Fault Current Rating (AIC)........................................ 200 kAIC 
 Operating 
Frequency 
Range.................................... 47 – 63 Hz 
 50 
 EMI/RFI Attenuation: 
 
 
Normal Mode .............................................. 10 kHz-500MHz  60 dB 
 
 
Common Mode ........................................... 10 kHz-500MHz   50 dB 
 Response 
Time ......................................................... <0.5 ns 
 Operating 
Humidity................................................... 0% to 95% 
 Status 
Indication ....................................................... LEDs, Dry Contacts, Audible Alarm, 
   
 
Surge 
Counter 
 Certifications ............................................................. UL 1449 & 1283, CSA 
 Enclosure 
.................................................................. NEMA 12 standard 
 Warranty 
.................................................................... 10-Years Parts / 5-Years Labor  
 Optional 
Equipment.................................................. Dual Surge Counter,  
   
Remote 
Monitor 
Panel
 
Dimensional data in inches and shipping weight in pounds 
Model/Configuration 
Dimensions in inches 
Wt 
 
Lbs 
30A Single Phase 
20.0 
16.0 9.0  21.25  10.0 .44  35 
30A Split or Three Phase 
24.0 20.0 9.0  25.25 14.0 .44  60 
60A Single Phase 
20.0 
16.0 9.0  21.25  10.0 .44  35 
60A Split or Three Phase 
24.0 20.0 9.0  25.25 14.0 .44  60 
100A Single Phase 
24.0 
20.0 9.0  25.25  14.0 .44  60 
100A Split or Three Phase 
30.0 24.0 9.0  31.25 18.0 .44  80 
225A Single Phase 
24.0 
20.0 9.0  25.25  14.0 .44  60 
225A Split or Three Phase 
30.0 24.0 9.0  31.25 18.0 .44  80 
400A Split or Three Phase 
48.0 36.0 12.0 49.25 30.0 .44  300 
800A Split or Three Phase 
60.0 
48.0 
12.0 
530 
1200A Split or Three Phase 
60.0 
48.0 
20.0 
750 
2000A Split or Three Phase 
60.0 
48.0 
20.0 
950 
4000A Split or Three Phase 
60.0 
48.0 
20.0 
1300 
Nominal 
Voltage Codes 
120 
120V 
208 
208V 
220 
220V 
230 
230V 
240 
240V 
277 
277V 
480 
480V 
600 
600V 
Source configuration 
1 Phase L-N 2w + gnd 
1 Phase L-L 2w + gnd 
Split Phase 3w + gnd 
3 Phase Wye 4w + gnd 
3 Phase Delta 3w + gnd 
3 Phase Delta Hi-leg 4w+ gnd 
F__ __ __    __    __ __ __ __    -   __ __  
Option Code 
01 
LED, Form C 
Contacts 
03 
LED, Alarm, Dual 
Counters, Form C 
Contacts 
06 
LED, Alarm, Counter, 
Form C Contacts 
Example Part Number:  
F277Y800-03
    = 277/480V, 3-Phase Wye, All Mode, 800 Amp Current Rating  
              LED’s, Alarm & Dual Counters, Form C Contacts 
Current 
Code 
Current 
Rating 
Surge Current Capability  
Per Phase 
30 
30A 100kA 
60 
60A 100kA 
100 
100A 150kA 
225 
225A 150kA 
400 
400A 150kA 
800 
800A 300kA* 
1200 
1200A 300kA* 
2000 
2000A 300kA* 
4000 
4000A 300kA 
* 200kA is available,  
add –200 to part number. 
Job Name____________________________
Model# ______________________________
Date ________________________________
Qty _________________________________
Quote# ______________________________
Life Cycle Surge Testing 
10kA, 20kV, IEEE Cat. C3 
Unit 
Per Mode (L-N/L-G/N-G) 
Per Phase 
100 kA 
12,000/12,000/12,000 
24,000 
150 kA 
12,000/24,000/24,000 
36,000 
200 kA 
24,000/24,000/24,000 
48,000 
300 kA 
24,000/48,000/48,000 
72,000