Справочник Пользователя для Canon GM-1000
![Canon](https://files.manualsbrain.com/attachments/4b6818c07b947b910f8cfb49338c2c63bdefaee1/common/fit/150/50/61ea34cb812b6780fe3b16f0b9221bd2f7635c65cee2473b66396d8b72cd/brand_logo.png)
CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20
Users Manual 1.20
32
2.8.3.1. Origin Offset
It is possible to change the origin position of high-speed serial communications.
Parameter ID
Data
15
High-speed serial communication
offset
Unit: pulse
Unit is pulse.
High-speed serial communication offset is not influenced by the parameter ID = 13 high-speed serial
communication conversion gain setting.
E.g.
When parameter ID = 15 setting 2276 pulse (=0.1°) is set, regardless of the parameter ID = 13 setting, it
will always operate with a 0.1° (CW direction) offset.
Note) Current position output data of Next heading 2.8.4. is actual motor encoder position data.
Current position output data
= High speed serial communication command position + High speed serial communication offset
So, Current position data is not equal to High speed serial communication command position that
you specify.