10 
The scanning range follows a rectilinear path and expands in the shape of an arc while 
centering (focusing) on a distant virtual reference point. 
PCS  Resolution (mm)  Decode Depth (mm)
0.9 1.0 
60–300 
 0.5 
35–210 
 0.25 
35–120 
 0.15 
35–70 
 
Resolution Symbology 
PCS 
Digit 
1.0 mm 
Code 39 
0.9 
1  
0.5 mm  
Code 39 
0.9 
3  
0.25 mm 
Code 39 
0.9 
8  
0.15 mm 
Code 39 
0.9 
10  
Conditions 
Scan angle 
54° (reading range is 44°) 
Detect angle 
40° 
Barcode sample 
Resolution 0.25 mm: OPTOELECTRONICS test sample. Code 39, 
9 digits 
Distance 
Within 90 mm from the minimum scannable distance 
Note: dirt or scratches on the mask will degrade scanning performance. Always handle 
the data collector carefully. 
Barcode Sample: OPTOELECTRONICS Test Sample 
N/W Ratio: 
1:2.5 
Angle: 
α = 0°, β = 15°, γ = 0° 
Curvature: R 
∞