APPENDIX B
REMOTELY MANAGING THE SYSTEM THROUGH AN RS-232 SERIAL INTERFACE
93
smarttech.com/kb/170911
Command
Response
Powered off
get vgacalibration
vgacalibration =
[current]
no
get waveformid
waveformid=[current]
no
get lampvoltage
lampvoltage =[current] no
get temperature
temperature =[current]
no
set temperaturereport
[target]
temperaturereport=
[current]
no
set
downloadlampdriver
[target]
downloadlampdriver=
[current]
no
clearfailurelog
no
set burnin
no
dwscaler#7537
no
Field definitions
Field
Possible Values
Description
target dbmsg
l
on
l
off
Turn on/off debug message.
current vgacalibration
l
???
To get the status of ADC calibration while
power on.
current waveformid
l
???
To get waveform ID while power on.
current lampvoltage
l
???
To get lamp voltage while power on.
current temperature
l
???
To get system temperature while power on.
target
temperaturereport
l
on
l
off
While set to on, the system temperature is sent
every five seconds (requires high-speed fan
mode to be on)
target
downloadlampdriver
l
done
Auto program waveform while standby
clearfailurelog
l
done
Clear all failure log for production burn in
preparation.
dwscaler#7537
Enter DDP download mode