Справочник Пользователя для SMART Technologies 880ix3 AND 885ix3

Скачать
Страница из 122
APPENDIX B
REMOTELY MANAGING THE SYSTEM THROUGH AN RS-232 SERIAL INTERFACE
68
smarttech.com/kb/170911
This appendix includes detailed instructions on how to set up your computer or room control
system to remotely manage the SMART Board interactive whiteboard system settings through an
RS-232 serial interface.
Connecting a room control system to the ECP
By connecting a computer or room control system to the 4-pin connector on the ECP, you can
select video inputs, start up or shut down the interactive whiteboard system and request
information such as projector lamp use, current settings and network addresses.
NOTE
On projectors with the RS-232 connector labeled Control 9v (rather than Control), pin 1 functions
as a +9V DC power source only for use with older model ECPs, such as the ones included with
SMART UF55 projectors.
Serial interface settings
The projector’s serial interface acts as a Data Communications Equipment (DCE) device, and its
settings can’t be configured. You must configure your computer’s serial communication program or
the room control system’s serial communication settings with the following values:
Setting
Value
Data Rate
19.2 kbps
Data Bits
8
Parity
None
Stop Bits
1
Flow Control
None
NOTES
l
Asynchronous mode is disabled by default in the projector.
l
All commands should be in ASCII format. Terminate all commands with a carriage return.
l
All responses from the projector are terminated with a command prompt. Wait until you
receive the command prompt indicating that the system is ready for another command
before you proceed.
l
The room control feature of the projector is always on.