Справочник Пользователя для GE 16

Скачать
Страница из 24
Installation Instructions
Install the shutoff  valve on the nearest frequently used drinking water line.
SHUT OFF THE MAIN WATER
SUPPLY AND UNPLUG
REFRIGERATOR
Turn on the nearest faucet (counterclockwise) long
enough to clear the line of  water.
1
11
Choose a location for the valve that is easily accessible. It
is best to connect into the side of  a vertical water pipe.
When it is necessary to connect into a horizontal water
pipe, make the connection to the top or side, rather than
at the bottom, to avoid drawing off  any sediment from
the water pipe.
Drill a 1/4” hole in the water pipe (even if  using a self-
piercing valve), using a sharp bit. Remove any burrs
resulting from drilling the hole in the pipe. Take care
not to allow water to drain into the drill. Failure to drill
a 1/4” hole may result in reduced ice production or
smaller cubes.
DRILL THE HOLE FOR THE VALVE
2
Fasten the shutoff  valve to the cold water pipe with the
pipe clamp.
Tighten the clamp screws until the sealing washer begins
to swell. 
NOTE: Do not overtighten or you may crush the
tubing.
NOTE: Commonwealth of  Massachusetts Plumbing
Codes 248CMR shall be adhered to. Saddle valves are
illegal and use is not permitted in Massachusetts. Consult
with your licensed plumber.
FASTEN THE SHUTOFF VALVE
3
Washer
Inlet End
Clamp Screw
Vertical Cold
Water Pipe
Saddle-Type
Shutoff Valve
Pipe Clamp
FLUSH OUT THE TUBING
Turn the main water supply on (counterclockwise) and
flush out the tubing until the water is clear.
Shut the water off  at the water valve after about 
one quart (1 liter) of  water has been flushed through the
tubing.
6
CONNECT THE TUBING 
TO THE VALVE
Place the compression nut and ferrule (sleeve) 
for copper tubing onto the end of  the tubing and
connect it to the shutoff  valve. 
Make sure the tubing is fully inserted into the 
valve. Tighten the compression nut securely.
For plastic tubing from a GE SmartConnect
Refrigerator Tubing kit, insert the molded end 
of  the tubing into the shutoff  valve and tighten
compression nut until it is hand tight, then tighten one
additional turn with a wrench. Overtightening may
cause leaks.
NOTE: Commonwealth of  Massachusetts Plumbing
Codes 248CMR shall be adhered to. Saddle valves are
illegal and use is not permitted in Massachusetts. Consult
with your licensed plumber.
5
Saddle-Type
Shutoff Valve
Compression
Nut
SmartConnect
Tubing
Packing Nut
Outlet Valve
Ferrule (sleeve)
ROUTE THE TUBING
Route the tubing between the cold water line and the
refrigerator.
Route the tubing through a hole drilled in the wall or
floor (behind the refrigerator or adjacent base cabinet) as
close to the wall as possible. 
NOTE: Be sure there is sufficient extra tubing (about 8
feet [244 cm] coiled into 3 turns of  about 10” [25 cm]
diameter) to allow the refrigerator to move out from the
wall after installation.
4