74  
Troubleshooting 
Table 10. Troubleshooting Matrix   Cartridge Movement with Solution 
Problem 
Solution 
Cartridge Movement 
Library does not take 
inventory 
 
Make sure the transport screws are removed. 
 
Make sure all magazines are in their locked position. 
 
Write down any error information given on the FPI or RMI. 
 
Contact your service representative. 
Cartridge stuck in drive 
 
Power cycle the library by turning off and on the main power 
switch on the rear of the library. Allow both the library and the 
drive to complete initialization, which in rare cases can take as 
long as 10 minutes, and then retry unloading the tape from the 
FPI or RMI. 
 
Make sure that the backup software is not reserving the slot or 
preventing the tape drive from ejecting the cartridge. The 
backup software needs to cancel the reservation and any hold it 
has on the tape drive. 
 
Temporarily disconnecting the library from the host server 
system eliminates the host system and its software as a 
problem source. 
 
Remove the tape drive unit from the drive bay. Connect power 
to the drive either by connecting it to the library s power supply 
or to an external power supply. Try to eject the cartridge by 
pushing the drive s eject button. The drive unit can be 
connected to the library s power supply by using the power 
extension cable located behind the battery holder cover plate 
on the rear of the library. 
 
Follow the drive s emergency eject procedure to remove the 
cartridge from the drive. 
 
Replace the tape drive unit. 
 
Contact your service representative. 
Cartridge stuck in magazine 
 
Eject the magazine using the front panel interface. Manually 
remove the cartridge from the magazine slot. 
 
Contact your service representative. 
Cartridge stuck in robotics 
 
Power cycle the library by turning off and on the main power 
switch on the rear of the library. 
 
Write down any error information given on the FPI or RMI. 
 
Contact your service representative. 
Failed to move cartridges 
 
Write down any error information given on the FPI or RMI. 
 
Contact your service representative. 
Failed to insert cartridge into 
drive 
Check failing media for pin damage (buckling pin). 
Hold the cartridge in your hand with the Write Protect Switch to your 
left and orientation arrow pointing away from you. On the right side 
all the way in front is a small door that can be opened by sliding a 
door against you. Inside the cartridge you should see a metal pin. 
The pin shall be parallel with the cartridge front and is hold in place 
by to metal grippers at each end (top and bottom of the cartridge). 
The media should be attached to this pin, and you see only the top 
and bottom part of the pin. If the pin is missing, loose or damaged 
the tape will be damaged and rejected from the drive.