Справочник Пользователя для Spectra LL300-2

Скачать
Страница из 9
7
Charging the batteries
The charger requires approx. 10 hours to charge empty rechargeable batteries. For this charging, connect the 
plug of the charger to the recharge jack of the unit. New or long-time out-of-use rechargeable batteries reach 
their best performance after being charged and recharged fi ve times. 
The batteries should only be charged when the laser is between 50° F and 104° F (10° C to 40° 
C) Charging at a higher temperature may damage the batteries. Charging at a lower temperature 
may increase the charge time and decrease the charge capacity, resulting in loss of performance 
and shortened life expectancy.
HOW TO USE THE LASER
Laser Setup
Position the unit horizontally (tripod mount and rubber feet downward!) on a stable platform, wall mount, or 
tripod at the desired elevation. 
Press the power button (1) to turn on the unit. The LEDs (3, 4 and 5) are turned on for 3 seconds. Self-leveling 
will start at once. The unit is leveled when the leveling indicator (3) is no longer fl ashing (once every second). 
The rotor will not spin until the unit is leveled. For the fi rst fi ve minutes after the laser self levels, the LED lights 
solid then fl ashes every four seconds to let you know the laser is still level.
In order to switch the unit off, press the power button (1) again.
If the laser is positioned beyond its self-leveling range of ±8%, the manual and leveling indicators fl ash 
simultaneously and a warning sound is emitted. Reposition the laser within its self-leveling range.
Self-leveling, Height Change (HI) Alert
Once turned on, the unit automatically levels itself in ranges of 8% (± 0.8 m / 10 m). In order to recognize 
the leveling process at the measuring area and in order not to mark faulty heights during this operation, the 
rotation stops. 
Once leveled, the unit constantly monitors its level condition. The height change (HI) alert is activated 5 minutes 
after self-leveling was performed and the laser is rotating at 600 min-1.
Level errors > 30 mm/10 m put the unit into alert mode because they are generally caused by a disturbance 
that could lead to inaccurate measurements. When entering into alert mode, the prism stops, the laser beam 
turns off, a warning sound is heard and the HI Warning LED (4) fl ashes 2 x per second. Turn the unit off and 
then on again. To ensure your former elevation, now you have to check or arrange the exact height. 
Manual Mode/Single Slope Mode
When you press the ‘M’ button (2) on the laser, the remote control, or the receiver-remote control, the laser is 
set from automatic self-leveling mode to Manual mode. Manual mode is indicated by the fl ashing (once every 
second) red LED (4). In Manual mode, the Y-axis can be sloped by pressing the Up- and Down-Arrow-buttons 
on the remote control. Additionally, the X-axis can be sloped by pressing the Left- and Right-Arrow-buttons 
on the remote control.
When you press the ‘M’ button again on the remote control, the laser is set into Single Slope mode. This is 
indicated by the fl ashing red (4) and green (3) LEDs (once every second). In Single Slope mode, the Y-axis 
can be sloped by pressing the Up- and Down-Arrow-buttons on the remote control, while the X-axis remains 
in automatic self leveling mode (e.g. when setting up ramps or drive ways). The Height change (HI) alert is 
still active.
Pressing the manual button at the laser or remote control again, changes the laser back to automatic self-
leveling mode as indicated by the fl ashing green LED (3).
041365_01_LL300_GB.indd   7
17.09.2004, 11:43:55 Uhr