Справочник Пользователя для Southbend sb1018

Скачать
Страница из 56
-42-
For Machines Mfg. Since 8/09
Model SB1018
E L E C T R I C A L
5.  Close the motor junction box and secure the 
cover with the provided screw.
6.  Use the 18mm wrench to remove the four 
hex bolts that secure the machine to the 
cabinet, then with the help of another per-
son, remove the machine from the cabinet. 
Carefully place the machine on its side to 
gain access to the underside of the base.
7.  Remove the black plastic switch cover from 
behind the switch. Disconnect the two wires 
from the back of the switch, then remove the 
switch.
8.  Install the 220V switch, then replace the two 
wires removed in Step 7 in the correspond-
ing locations from which they were removed.
9.  Replace the switch cover, then with the help 
of another person, place the machine back 
onto the cabinet and secure it with the hex 
bolts removed in Step 6.
3.  Use a wire nut to connect wires #2, #3, and 
#5, then wrap the wires and nuts with elec-
trical tape.
4.  Connect wires #1 and #6 to the upper right 
terminal and wire #4 to the lower right 
terminal shown in Figure 54. Tighten the 
terminal screws to secure the wires.
Figure 54. Rewired for 220V.
Start
Capacitor
200MFD
125VAC
6
1
4
Start
Capacitor
200MFD
125VAC
5
2
3
6
1
4
5
2
3
Neutral
Hot
GND
Ground
Motor (Prewired 110) 
Motor (Rewired for 220V)  
110 VAC
5-15 Plug
(As Recommended)
OVERLOAD
RESET
OVERLOAD
RESET
1
2
3
4
GND
GND
GND
ON/OFF
SWITCH
Hot
Hot
Ground
220 VAC
6-15 Plug
(As Recommended)
1
2
3
4
GND
GND
ON/OFF
SWITCH
220V 
Wiring
Tighten These 
Terminal Screws
Items Needed 
Qty.
220V Switch (Part No. PSB1018204) ...................1
Phillips Screwdriver #2 ........................................1
Wrench 18mm .......................................................1
Wire nut (sized for three 14 Ga. wires) ................1
Electrical Tape .......................................As needed
Wire stripper ..........................................As needed
To convert the Model SB1018 to 220V:
1.  DISCONNECT BANDSAW FROM POWER!
2.  Open the motor junction box, then loosen the 
wire terminals indicated in Figure 53. Re-
move the wires connected to those terminals.
Figure 53. Wiring terminal locations.
Start
Capacitor
200MFD
125VAC
6
1
4
Start
Capacitor
200MFD
125VAC
5
2
3
6
1
4
5
2
3
Neutral
Hot
GND
Ground
Motor (Prewired 110) 
Motor (Rewired for 220V)  
110 VAC
5-15 Plug
(As Recommended)
OVERLOAD
RESET
OVERLOAD
RESET
1
2
3
4
GND
GND
GND
ON/OFF
SWITCH
Hot
Hot
Ground
220 VAC
6-15 Plug
(As Recommended)
1
2
3
4
GND
GND
ON/OFF
SWITCH
110V Wiring
Loosen These 
Terminal Screws
Wiring diagrams are provided in this section 
showing the Model SB1018 wired for both 110V 
and 220V. Refer to these diagrams if needed 
when following this procedure. Additionally, 
you must purchase a 220V switch (Part 
No. PSB1018204) in order to complete the 
conversion.
220V Conversion
READ PAGE 41 BEFORE 
DOING ANY WIRING!