Справочник Пользователя для Intel SERVER CHASSIS SR2500 SR2500
Модели
SR2500
Environmental and Regulatory Specifications
Intel® Server System SR2500AL
Revision – 1.00
Intel order number D31980-004
88
10.5 Serviceability and Availability
The system is designed to be serviced by qualified technical personnel only.
The desired Mean Time To Repair (MTTR) of the system is 30 minutes including diagnosis of
the system problem. To meet this goal, the system enclosure and hardware have been
designed to minimize the MTTR.
the system problem. To meet this goal, the system enclosure and hardware have been
designed to minimize the MTTR.
Following are the maximum times that a trained field service technician should take to perform
the listed system maintenance procedures, after diagnosis of the system and having identified
the failed component.
the listed system maintenance procedures, after diagnosis of the system and having identified
the failed component.
Activity
Time
Estimate
Remove cover
1 min
Remove and replace hard disk drive
5 min
Remove and replace power supply module
1 min
Remove and replace system fan (non-hot swappable)
7 min
Remove and replace system fan (hot swappable)
1 min
Remove and replace backplane board
12 min
Remove and replace midplane board
10 min
Remove and replace control panel module
2 min
Remove and replace server board
15 min
10.6 Restriction of Hazardous Substances (RoHS) Compliance
Intel has a system in place to restrict the use of banned substances in accordance with the
European Directive 2002/95/EC. Compliance is based on declaration that materials banned in
the RoHS Directive are either (1) below all applicable substance threshold limits or (2) an
approved/pending RoHS exemption applies.
European Directive 2002/95/EC. Compliance is based on declaration that materials banned in
the RoHS Directive are either (1) below all applicable substance threshold limits or (2) an
approved/pending RoHS exemption applies.
Note: RoHS implementing details are not fully defined and may change.
Threshold limits and banned substances are noted below.
• Quantity limit of 0.1% by mass (1000 PPM) for:
o
Lead
o
Mercury
o
Hexavalent
Chromium
o
Polybrominated Biphenyls Diphenyl Ethers (PBDE)
• Quantity limit of 0.01% by mass (100 PPM) for:
o
Cadmium