Справочник Пользователя для Intel SERVER CHASSIS SR2500 SR2500

Модели
SR2500
Скачать
Страница из 115
Intel® Server System SR2500AL Power 
Sub-System 
Revision – 1.00 
 
 
Intel order number D31980-004 
13
2.5  Airflow   
Each power supply module incorporates two non-redundant 40mm fans for self cooling and 
partial system cooling.  The fans will provide no less than 10 CFM airflow through the power 
supply when installed in the system and operating at maximum fan speed. The cooling air will 
enter the power module from the PDB side (pre-heated air from the system). 
2.6  AC Power Cord Specification Requirements 
The AC power cord used must meet the following specification requirements: 
Cable Type 
SJT 
Wire Size 
16 AWG 
Temperature Rating 
105º C 
Amperage Rating 
13A 
Voltage Rating 
125V 
 
2.7  Output Cable Harness 
The power distribution board provides a cable harness providing connectors to the various 
system boards.  The harness size, connectors, and pin outs are shown below.  Listed or 
recognized component appliance wiring material (AVLV2), CN, rated 105
°
C min, 300Vdc min 
shall be used for all output wiring.   
Table 2. Power Harness Cable Definitions 
Length 
mm  
To 
connector # 
No of 
pins 
Description 
90, 90° 
angle 
P1 
2x12 
Main Power Connector 
115, 90° 
angle  
P2 
2x4 
Processor Power Connector 
100 
P3 
1x5 
Server Board Signal Connector  
150 
P4 
2x4 
Backplane Power Connector  
220 
P5 
2x5 
Mid-plane Power Connector