Справочник Пользователя для Graco Inc. 288046

Скачать
Страница из 40
Service 
20
311052E
Service
Items Needed for Service
1/16 in. Hex Wrench - provided
3  mm  Hex  Wrench
Adjustable Wrench
4  mm  Hex  Wrench
5/16 in. Nut Driver
Pliers
Lubricant part no. 111265; see Accessories, page 
34, to order
Compatible Solvent
Disassembly
1.
2.
Unscrew the four screws (17) and remove the gun 
from the manifold.
3.
Unscrew the air cap retainer (8). Remove the air cap 
(30) and spray tip (9). See F
Model 288053: Unscrew the air cap (30). Remove 
the RAC spray tip (9) and RAC housing (11). See 
Parts, page 25.
4.
Inspect the tip seal (9a) in place. If damaged, 
replace the tip seal.
5.
Remove the cap (27) from the piston housing (1). 
Remove the springs (28 and 29).
6.
Using the supplied wrench (38), loosen the fluid 
needle setscrew (19). Remove the needle stop (21). 
7.
Trigger the gun (or remove cap (27) and springs (28, 
29)) to pull the needle housing off the seat while you 
unscrew the diffuser (10) from the gun body (1).
8.
Unscrew the needle assembly (14) and use 5/16 in. 
nut driver to pull the assembly straight out the front 
of the gun.  
9.
Remove the piston. Using a pliers, pull the piston 
(20) out of the piston housing (1). See F
Follow the Service Notes in F
. 17 and F
when reassembling the gun. 
Gun repair kits are available. See page 34. Refer-
ence numbers marked with an asterisk (*) in the 
service procedures are included with the 288171 
Air Seal Repair Kit. Reference numbers marked 
with a symbol (†) in the service procedures are 
included with the 288136 Fluid Repair Kit.
CAUTION
Be sure to keep the needle straight when removing it 
from the gun. If the needle is bent, it must be 
replaced.