Super Finish 23 PLUS
 
1
2
3
4
GB
STARTUP
4.5 
CLEANING PRESERVING AGENT WHEN 
STARTING-UP OF OPERATION INITIALLY
Unit with suction tube
1.  Immerse the suction system into a container filled with a 
suitable cleaning agent (recommendation: water).
Unit with hopper
2.  Fill up hopper with a suitable cleaning agent (recommen-
dation: water).
3.  Set multifunction switch (1) to 
 (ON– circulation); the 
unit commences to run.
4.  Turn the pressure regulating knob (2) to the right until 
the stop is reached.
5.  Wait until cleaning agent is emitted from the return hose.
6.  Turn the pressure regulating knob (2) back approx. one 
rotation.
7.  Set multifunction switch (1) to 
 (spray). 
Pressure is rising up inside the high pressure hose (visible 
at pressure gauge)
8.  Point the tip of the spray gun into an open collecting con-
tainer and pull the trigger guard at the spray gun.
9.  The pressure is increased by turning the pressure regulat-
ing knob (2) to the right. Set approx. 10 MPa (100 bar) at 
the pressure gauge.
10. Spray the cleaning agent out of the unit for approx. 
1 - 2 min. (~5 litres) into the open collecting container.
4.7 
TAKING THE UNIT INTO OPERATION WITH 
COATING MATERIAL
Unit with suction tube
1.  Immerse the suction system into a container filled with 
coating material.
Unit with hopper
2.  Fill coating material into the hopper.
3.  Press inlet valve pusher (4) several times to release pos-
sibly clogged inlet valve
4.  Set multifunction switch (1) to 
 (ON - circulation); the 
unit will start.
5.  Turn the pressure regulating knob (2) to the right until 
the stop is reached.
 
When the noise of the valves changes, the unit is bled and 
takes in coating material.
6.  If coating material exits from the return hose, turn the 
pressure regulating knob (2) back approx. 1 rotation.
7.  Set multifunction switch (1) to 
 (spray). 
 
Pressure is rising up inside the high pressure hose (visible 
at pressure gauge (3)).
8.  Pull of the spray gun and spray into an open collecting 
container in order to remove the remaining cleaning 
agent from the unit. When coating materials exits from 
the tip, close the spray gun.
9.  Adjust the spraying pressure by turning the pressure reg-
ulating knob (2).
10.  The unit is ready to spray.
4.6 
VENTILATE UNIT (HYDRAULIC SYSTEM) IF THE 
SOUND OF INLET VALVE IS NOT AUDIBLE
1.  Switch on the unit.
2.  Turn pressure regulating knob (2) three revolutions to 
the left.
3.  Set multifunction switch (1) to 
 (ON – circulation). The 
hydraulic system is ventilated. Leave the unit on for two to 
three minutes.
4.  Then turn pressure regulating knob (2) to the right until 
stop.
5.  Press inlet valve pusher (4).
 
Sound of the inlet valve is audible.
6.  If not, repeat points 2 and 4