H.E.R.O. INDUSTRIES                                                  1100C & 1100NC OWNERS MANUAL  
SYSTEM, EVEN OVERNIGHT.    
     
                          
ý    NEVER attempt to start the motor when the unit is under pressure. Relieve pressure and follow     
        instructions in "Setting up to spray" 
ý    NEVER attempt to run the motor on longer or lighter extension cord than specified. 
ý Avoid operating the unit while tilted. Keeping it level assures greater operating efficiency. 
þ    If motor's thermal overload switch has opened, unplug unit and allow it to cool. 
ý DO NOT attempt to resume spraying before determining and correcting the cause of overheating. 
þ Always follow flushing and cleaning instructions exactly. 
þ In hot weather, locate unit in shade. 
þ Regularly check the level of H.E.R.O. LVO hydraulic fluid in the hydraulic tank. It should be kept near 
        full, top up as needed with only genuine H.E.R.O. LVO hydraulic fluid. 
þ Crankshaft eccentric bearing should be greased at regular intervals consistent with hours of use. Use   
        MO-2 grease (i.e. common auto grease) approximately every 10 hours of operation. 
þ
  Check drive belt ( part # 66/100 ) tension frequently. The belt will stretch with use, and should be 
  adjusted after 20 hours of operation and again after 50 hours. Periodic checks after 50 hours should be 
  made. A slipping belt will reduce sprayer performance and the tension should be checked frequently. 
þ
  Regularly check fittings, bolts, nuts and connections for damage. Tighten, adjust or replace as required.   
þ
  Check crankshaft alignment often. An out of alignment crankshaft will cause the damage to the 
  eccentric bearing.  
þ If you wish to power your H.E.R.O. airless sprayer with a generator, it must be a minimum of a 5000 
        watt generator, in good operating condition.  
        NOTE;  An electric tool must be powered by a generator which has an output wattage of at least three 
        times the maximum draw of the motor under full load.  
þ A minimum 50’ and a maximum of 300’ of airless spray hose may be used. 
        NOTE:  50’ x  3/8” paint hose ( part # 117 ) should be used for every 50’ x 1/4” paint hose 
        ( part # 114 ) over 100’. 
        100’ total length of paint hose = 2 of 50’ x 1/4” paint hose.   
        150’ total length of paint hose = 2 of 50’ x 1/4” paint hose and 1 of 50’ x 3/8 paint hose. 
        200’ total length of paint hose = 2 of 50’ x 1/4” paint hose and 2 of 50’ x 3/8 paint hose.   
        250’ total length of paint hose = 3 of 50’ x 1/4” paint hose and 2 of 50’ x 3/8 paint hose.        
        300’ total length of paint hose = 3 of 50’ x 1/4” paint hose and 3 of 50’ x 3/8 paint hose.                                                                                                                         
þ    Product viscosity, altitude ( feet above sea level ) and vertical reach can effect pump performance and  
        special accessories may be required. Product viscosity may have to be further reduced at higher 
        elevations. The larger diameter 3/8” paint hose should also be used,  to aid in the movement of spray 
        materials. 
 
 
 
 
 
                                         AIRLESS SPRAY PAINTING 
                                  SUGGESTIONS AND TECHNIQUE 
 
A good airless spray application is the result of many factors. Surface preparation, which includes cleaning 
and degreasing, priming, material compatibilit y, quality finish product and correct application technique. All 
are all important to the finished results.