Справочник Пользователя для Echo HC-235

Скачать
Страница из 32
16
aIr
 
fIlter
Level 1.
Tools required:  25 or 50 mm (1 or 2 in.) cleaning brush
Parts required:    REPOWER
TM
 AIR & FUEL FILTER KIT.
1.  Close choke (Cold Start Position [
]). This prevents dirt from 
entering the carburetor throat when the air filter is removed. Brush 
accumulated dirt from air cleaner area.
2.  Remove air filter cover. Brush dirt from inside cover.
3.  Remove air filter and lightly brush debris from filter. Replace filter 
if it is damaged, fuel soaked, very dirty, or the rubber sealing edges 
are deformed.
4.  If filter can be reused, be certain it:
  • Fits tightly in the air filter cavity.
  • Is installed with the original side out.
5.  Install air filter cover.
NOTE 
Carburetor adjustment may be needed after air filter cleaning/re-
placement.
fuel
 
fIlter
Level 1.
Tools required:    200-250 mm  (8-10 in.) length of wire with one end 
bent into a hook, clean rag, funnel, and an approved 
fuel container
Parts required:    REPOWER
TM
 AIR & FUEL FILTER KIT.
  DANGER
Fuel is VERy flammable. Use extreme care when mixing, storing 
or handling.
1.  Use a clean rag to remove loose dirt from around fuel cap and 
empty fuel tank.
2.  Use the “fuel line hook” to pull the fuel line and filter from the tank.
3.  Remove the filter from the line and install the new filter.