■Commands and responses 
・  Instructions sent to the controller are called commands. 
・  Messages returned from the controller are called responses. 
・  The communications are two-way. (When a command is sent, a response is always returned.) 
・  Data is sent in ASCII format. 
 
 
・  When  a  response  is  not  received,  this  indicates  that  the  transmission  format  is  wrong,  the 
command  has  not  yet  reached  its  destination,  or  the  controller  is not  in  operation.  Check  the 
communication specifications, such as the transmission speed, data lengths, and parity. 
・  When a response with “!” instead of “$” stored is received, it indicates that the command has 
not been processed correctly. Check the communication error code stored in the response to 
identify the error. 
 
■  Command/response format 
 
Command message                             
 
 
 
 
                        
                                                
 
 
  
 
 
  
 
 
  
 
 
  
 
 
  
 
 
  
 
 
  
 
 
  
 
 
  
 
 
  
 
 
  
 
 
  
 
■Block check code BCC (H) (L) 
  Binary hexadecimal 00-FF (ASCII-encoded) 
・To improve the reliability of transmission data, this encoding enables error detection using longitudinal parity 
bits. However, if  “**” appears instead of BCCs, transmission is possible without BCCs. Even in this case, 
however, BCCs will be included in the response. 
・BCCs are created by taking the exclusive OR from the header (<) to the final character of the text, and then 
encoding this 8-bit word into a 2-character ASCII code.