Справочник Пользователя для Siemens L-850D/E F-Range Style 2 Inset Lights

Скачать
Страница из 46
L-850D/E F-Range Style 2 Inset Lights 
Installation on FAA Deep Bases
 2002 Siemens Airfield Solutions, Incorporated
96A0266D
15
All rights reserved
Issued 2/02
Mounting and connection
To mount and connect the light assembly, proceed as follows:
Step
Action
1
Clean the contact surfaces between the light assembly and adapter
ring and particularly its O-ring groove.
Apply a light coat of neutral vacuum type silicone grease (Siemens
Airfield Solutions PN 7850.42.210) to a new, clean O-ring gasket (E6).
2
Place the O-ring carefully in its groove.
 Never reuse an already used gasket.
3
Connect the light by inserting its two-pole plug(s) into the secondary
receptacle(s) of the transformer(s), already installed in the base and
connected to the primary series circuit.
4
Gently install the light fixture in the base using one of the lifting devices
(see page 19).
5
Make sure that the washers are mounted correctly to avoid denting the
cover.
6
Torque down gradually and crosswise the 6 screws and washers (A1-
A2) or self locking nuts. Refer to the table “Screws Overview” page 43
for the tool to use, the torque to apply and the eventual use of
“Loctite”.
Make sure not to pinch the wires when mounting of the light fixture on the adapter
ring.
How to mount
the light
assembly