Справочник Пользователя для Siemens L-850D/E F-Range Style 2 Inset Lights

Скачать
Страница из 46
L-850D/E F-Range Style 2 Inset Lights 
Servicing in Maintenance Base
 2002 Siemens Airfield Solutions, Incorporated
96A0266D
25
All rights reserved
Issued 2/02
How to replace the cable set assembly
Only use Siemens Airfield Solutions cable sets. Usage of substitutes voids the
warranty.
To replace the cable set assembly, proceed as follows (for the tools to use, refer to
page 43 “Screws Overview”):
Step
Action
1
Remove the optical assembly as described on page 24.
2
Remove both screws (E9) and the wire clamp (E8).
3
Cut the fast-on connectors (E3) from the cable assembly.
4
Pull the cable assembly out of the inner cover (E5) and discard the
grommets (E7).
5
Bring the new Siemens Airfield Solutions cable assembly through the
wire clamp (E8).
 One wire per hole.
6
Put a new wire grommet (E7) on each of the wires, taking care of the
direction (the smaller diameter into the inner cover recesses).
7
Introduce the wires in the inner cover.
8
Reinstall the wire clamp (E8) by means of both cross recessed pan head
screws (E9).
Do not torque down the screws entirely at this step.
9
Remove the insulation of the wires over about 5 mm.
10
Crimp on new fast-on spade connectors (E3, Siemens Airfield Solutions
code Nr 6111.87.140) and connect to the terminals. Adjust the wires
inside the inner cover.
11
Torque the screws (E9).
Refer to the table “Screws Overview” on page 43 for the tool to use, the
torque to apply, and the eventual use of “Loctite” sealing compound.
Siemens Airfield
Solutions cable
sets
Procedure