Справочник Пользователя для Ingersoll-Rand LM2350E-XX-B

Скачать
Страница из 4
LM2350E-X-B
Page 2 of 4
PARTS LIST / LM2350E-XX-B
Item Description
(size in inches)
Qty Part No.
[Mtl]
Item Description
(size in inches)
Qty Part No.
[Mtl]
1 Carriage Bolt
(1/4” - 20 x 9” long)
(4) 94333
[C]
2 Upper Cap
(1) 94390
[Z]
n
3 Track Gasket
(2) 94392
[B]
4 Sleeve
(2) 94316
[Br]
n
5 “O” Ring
(1/16” x 11/16” o.d.)
(4) Y325-15
[B]
n
6 “O” Ring
(1/8” x 3/4” o.d.)
(4) Y325-206
[B]
7 Spool
(2) 94310
[D]
n
8 “U” Cup
(1/8” x 3/4” o.d.)
(2) Y240-7
[B]
n
9 “O” Ring
(.106” x .587” o.d.)
(2) 15066-PM [B]
10 Cylinder
(1) 94306
[A]
11 Adapter
models LM2350E-X1-B
(1) 94384
[C]
models LM2350E-X2-B
(1) 94384-1
[C]
n
12 “O” Ring
(1/16” x 3/4” o.d.)
(1) Y325-16
[B]
n
13 “O” Ring
(1/16” x 7/16” o.d.)
(1) Y325-11
[B]
14 Muffler Housing
(1) 94443
[A]
15 Foam Liner
(2) 94402
16 Edge Trim
(2) 94378-1
[N]
18 Retaining Ring
(1) 94406
[C]
19 Washer
(1) 94515
[C]
n
20 “U” Cup
(3/16” x 3” o.d.)
(2) 94518
[B]
21 Piston
(1) 94403
[D]
23 Piston Adapter
(1) 94388
[C]
n
24 “O” Ring
(3/32” x 1” o.d.)
(1) Y325-117
[B]
25 Dowel Pin
(1/4” o.d. x 7/8” long)
(1) Y148-37
[C]
26 Washer
(1) 94785
[C]
n
27 “O” Ring
(3/32” x 11/16” o.d.)
(1) Y325-112
[B]
28 Spring
(1) 94705
[C]
n
29 Rod Seal
(1) 93921
[U]
30 Base
models LM2350E-X1-B
(1) 67188
[C/Z]
models LM2350E-X2-B
(1) 67188-1
[C/Z]
31 Nut
(1/4” - 20)
(4) 93828
[SS]
32 Ground Screw
(#10 - 32 x 1/4”)
(1) 93005
[C]
n
33 Gasket
(1) 70834
[Co]
34 Extension Tube
- LM2350E-2X-B (7.531’’)
(1) 94401-2
[C]
- LM2350E-3X-B (20.281’’)
(1) 94401-3
[C]
- LM2350E-4X-B (28.781’’)
(1) 94401-4
[C]
- LM2350E-6X-B (10.281’’)
(1) 94401-6
[C]
- LM2350E-7X-B (18.531’’)
(1) 94401-7
[C]
- LM2350E-8X-B (27.781’’)
(1) 94401-8
[C]
n
35 Gasket
(1) 70837
[Co]
36 Piston Rod
(1) 94385
[C]
37 Pin
(1) 94786
[C]
n
38 Cotter Pin
(1/16” x 1/2” long)
(1) Y15-21
[C]
39 Connector
- LM2350E-2X-B (3.457”)
(1) 94340-2
[C]
- LM2350E-3X-B (16.207”)
(1) 94340-3
[C]
- LM2350E-4X-B (24.707”)
(1) 94340-4
[C]
- LM2350E-6X-B (6.207”)
(1) 94340-6
[C]
- LM2350E-7X-B (14.457”)
(1) 94340-7
[C]
- LM2350E-8X-B (27.707”)
(1) 94340-8
[C]
Piston & Tube Ass’y
(includes 40 - 44)
(1) 71523-1
40 Lower Suction Tube
(1)
[C]
41 Plunger
(1)
[C]
42 Ball Stop
(1) 83276
[C]
43 Ball
(9/32” dia.)
(1) Y16-209
[C]
44 Adapter
(1) 70817-11
[C]
n
45 Guide Washer
(1) 71524-1
[Co]
46 Spacer
(1) 72392-1
[C]
47 Retaining Ring
(.763” o.d.)
(1) Y147-68
[C]
48 “U” Cup
(3/16” x 11/16” o.d.)
(1) Y186-4
[B]
49 Guide Spacer
(1) 76705
[T]
50 Valve Body
(1) 76704
[SH]
n
Foot Valve Ass’y
(includes 47 - 50)
(1) 60940
n
51 Gasket
(1) F21-65
[Co]
52 Valve Seat
(1) 6797
[C]
53 Primer Rod
(1) 94446
[C]
n
54 Retainer Ring
(1) 94397
[C]
55 Primer
(1) 94400
[C]
56 Primer Tube
(1) 94399
[C]
:
57 Bung Assembly
(includes 58)
(1) 67145-2
[ZA]
:
58 Thumb Screw
(1/4” - 20 x 1”)
(3) Y66-59-C
[C]
:
Not included with models LM2350E-6X-B
n
Gadus S2 U1000 Grease Packet (1) 94833
n
Parts in Repair Kit
637227-B
OPERATING AND SAFETY PRECAUTIONS
WARNING EXCESSIVE INLET PRESSURE. Can cause ex-
plosion resulting in severeinjury ordeath. Do not exceed maxi-
mum operating pressure of 7500 p.s.i. (517.2 bar) at 150 p.s.i.
(10.3 bar) inlet air pressure. Do not run pump without using a
regulator to limit air supply pressure to the pump.
WARNING EXCESSIVE MATERIAL PRESSURE. Can cause
equipment failure resulting in severe injury or property dam-
age. Do not exceed the maximum material pressure of any
component in the system.
Replacement warning label is available upon request, PN \ 94520.
PUMP RATIO X
INLET PRESSURE TO PUMP MOTOR
=
MAXIMUM PUMP
FLUID PRESSURE
Pump ratio is an expression of the relationship between the pump motor area and
the lower pump end area. EXAMPLE: When 150 p.s.i. (10.3 bar) inlet pressure is
supplied to the motor of a 50:1 ratio pump it will develop a maximum of 7500 p.s.i.
(517.2 bar) fluid pressure (at no flow) -- as the fluid control is opened, the flow rate
will increase as the motor cycle rate increases to keep up with the demand.
NOTICE: Thermal expansion can occur when the fluid in the materi-
al lines is exposed to elevated temperatures. Example: Material
lines located in a non-insulated roof area can warm due to sunlight.
Install a pressure relief valve in the pumping system.