Справочник Пользователя для Fisher & Paykel DS603

Скачать
Страница из 47
March 2004
Manual 599082
- 21 -
Press Power to Exit at any time (All outputs will be switched off on exit).
As mentioned above the LCD display and touch switch panel LED’s are illuminated to correspond to a particular
hardware device.  The following table details the display order of the test.
LCD
Norm
Fast
Deli
Rinse
Hardware Output
-------------------------------------------------------------------------------------------
bL
  Off
  Off
  Off
  On
Backlight
Er
  Off
  Off
  On
  Off
Element Relay
Ld
  Off
  Off
  On
  On
Lid Motors 
(will run for 10 seconds)
dd
Off
  On
  Off
  Off
Detergent Diverter Valve
FU
  Off
  On
  Off
  On
Fill Water Valve
P1
  Off
  On
  On
  Off
Motor Wash direction
(2300-2850 rpm)
P2
  Off
  On
  On
  On
Motor Drain direction
(4200 rpm)
rd
On
  Off
  Off
  Off
Rinse Aid Dispenser 
(dispenses
current setting)
dF
  On
  Off
  Off
  On
Drying fan
LE
  On
  Off
  On
  Off
Rinse Aid LED
C1
  On
  Off
  On
  On
Water Softener Diverter Valve
C2
  On
  On
  Off
  Off
Water Softener Brine Pump
°C
 
 
On
  On
  Off
  On
Displays current water
temperature.
°E
 
 
On
  On
  On
  Off
Displays controller rail voltage
(C3 is used in the Factory to empty the Water Softener before the Product is packed.)
WARNING :  In diagnostic mode there is no component protection.  Therefore take care when running individual
components not to overload them.  It is advisable to avoid turning the element on without filling the tub with water
first.
NB : 
No Fault codes will come up while in diagnostics mode.
Tub Home Sensor Test:  At any time during HO test mode the Keylock symbol on the LCD display (Keylock LED
on integrated badge)
 indicates the tub position. On = Closed, Off = Open.
5.1.5
Fast Test Cycle
WARNING :  only run this cycle if connected to the water supply
This level runs a 5 minute fast test cycle.
Press Power to skip Fast Test Cycle and advance to the next level.
Press Start/Pause to enter Fast Test cycle.
Once Fast Test Cycle is selected the DishDrawer goes into standby mode and 5 minutes will be showing on the
display. The test cycle is started by pushing Start/Pause and the following components are run during the 5 minute
cycle that follows:- Lid motors, fill valve, wash motor, element, drain motor.
Press Power to Exit at any time.
5.1.6
Continuous Cycle Test Mode
In this level the DishDrawer can be run continuously in any wash cycle.  Once the cycle has finished, the DishDrawer
automatically restarts the same wash cycle.
Press Power to skip Continuous Cycle. As this is the last level, doing this will exit diagnostics.