6.0 DIAGNOSTICS QUICK REFERENCE CHARTS
6.1
Fault Display/Download Mode:-
Press and hold Keylock, then Start/Pause for 5 seconds
All LEDs & LCD segments except Keylock are illuminated
Press Start / Pause
This initiates Pen upload via lower tub-home light pipe. At the same time the current and then the previous fault code
will be displayed in the LCD screen & on the secondary control panel LEDs.  To read the fault code on the
secondary display refer to Section 7.1 on Fault Codes.
Press Keylock
This will clear current fault code. Note if you press Keylock again you will remove the previous fault
Press Power
To exit
6.2
Hardware Output Test Mode:-
Press and hold Keylock, then Start/Pause for 5 seconds
All LEDs & LCD segments except Keylock are illuminated
Press Power Button Once
HO will show in the display 
(integrated: Heavy, Normal, Fast, Delicate, Rinse LEDs showing)
Press Start/Pause
Scroll through the following outputs using Start/Pause. Turn the outputs on & off using Keylock button.
Press Power
To exit
Note: Scrubbing Brush = output on, No Scrubbing Brush = output off (on integrated models a green LED above the start/pause button is
used inplace of the scrubbing brush)
LCD
Norm
Fast
Deli
Rinse
Hardware Output
Display
  
LED
 
LED
 LED
  LED
-------------------------------------------------------------------------------------------
bL
  Off
  Off
  Off
  On
Backlight
Er
  Off
  Off
  On
  Off
Element Relay
Ld
  Off
  Off
  On
  On
Lid Motors (will run for 10 seconds)
dd
Off
  On
  Off
  Off
Detergent Diverter Valve
FU
  Off
  On
  Off
  On
Fill Water Valve
P1
  Off
  On
  On
  Off
Motor Wash direction (2300-2850 rpm)
P2
  Off
  On
  On
  On
Motor Drain direction (5000 rpm)
rd
On
  Off
  Off
  Off
Rinse Aid Dispenser (dispenses current setting)
dF
  On
  Off
  Off
  On
Drying fan
LE
  On
  Off
  On
  Off
Rinse Aid LED
C1
  On
  Off
  On
  On
Water Softener Diverter Valve
C2
  On
  On
  Off
  Off
Water Softener Brine Pump
°C
  On
  On
  Off
  On
Displays current water temperature.
°E
  On
  On
  On
  Off
Displays controller rail voltage
Tub Home Sensor test:- keylock symbol on = tub closed, off = tub open