Illustration Component
Test
Procedure
Results
Dispenser wax motor
120V with 1/4"
actuation stroke
within 90 seconds
120V with 1/4"
actuation stroke
within 90 seconds
Measure resistance from J6 Pin 3
Tan (Dispenser) to ST4 Black
(Common) .........................................
Tan (Dispenser) to ST4 Black
(Common) .........................................
2 k
Ω
Limit Thermostat
Close on Temperature drop @ 149°F
± 7°F (Temp) .......................................
Open on Temperature drop @ 164°F
± 4°F (Temp) .......................................
± 7°F (Temp) .......................................
Open on Temperature drop @ 164°F
± 4°F (Temp) .......................................
0
Ω = Closed
Infinite
Ω = Open
Sensor/Thermistor
10K
Ω ± 3% at 77°F and 2.4 k Ω ±
6.5% at 140°F
J5 pin 1 - Orange (Temp) to J5 Pin 4 -
Red (Neutral) .......................................
J5 pin 1 - Orange (Temp) to J5 Pin 4 -
Red (Neutral) .......................................
Infinite
Ω = Open
0
Ω = Closed
Heater/Heating
Element
120v/60hz, 650 watts
± 5% in air, 830 watts
± 5% in 90°F water
Element
120v/60hz, 650 watts
± 5% in air, 830 watts
± 5% in 90°F water
Measure resistance from ST1
Red/Black (Heater) to ST11 White
(Common) ...........................................
Red/Black (Heater) to ST11 White
(Common) ...........................................
16
Ω
(This value assumes the high limit
thermostat is closed).
thermostat is closed).
Drain Motor
120v/60hz
45 watts
120v/60hz
45 watts
Measure resistance from
ST6 Gray (Drain) to ST4 Black
(Common) ...........................................
ST6 Gray (Drain) to ST4 Black
(Common) ...........................................
25
Ω