Справочник Пользователя для CMA Dishmachines MODEL GL-C

Скачать
Страница из 11
Maintenance
   
6. Maintenance 
6.1. Troubleshooting 
 
PROBLEM LIKELY 
CAUSE 
SOLUTION 
Power off at circuit breaker 
Reset circuit breaker 
Drive motor burn out 
Replace drive motor 
Obstruction in wash or rinse 
Remove obstruction 
Micro switch on switch support 
bracket faulty or not making 
contact 
Replace or adjust 
Conveyor doesn’t turn 
Conveyor not in position 
Position properly 
Splash curtain not in position 
Install or adjust 
Washer running without any 
glasses on conveyor 
Keep conveyor loaded with 
glasses 
Spray tubes fallen off hub 
Ensure spray tube is pushed 
firmly on to hub connection 
Excessive overspray from 
hood section 
Spray tubes plugged 
Clear and clean with reamer, 
scraper, and brush 
No water in detergent tank 
Ensure water supply is on 
Ensure detergent tank stand 
pipe is in position 
Ensure the tank fill switch is in 
On-Fill position and that tank 
fills with water 
Ensure the float switch is 
activated by the float cam 
Ensure the tank fill solenoid is 
operational 
Obstruction in wash arm 
Clear obstruction
 
Pump not operating 
Check power supply to 
machine 
Check pump capacitor 
Replace pump if required 
Lack of pressure in wash 
spray tubes 
Pump operating but no pressure 
Check condition of impeller 
and stub shaft 
Replace if needed 
Rinse spray tubes dirty 
Clean thoroughly with reamer, 
scraper, and brush provided 
Shut-off valve on supply line 
closed 
Open valve 
Lack of pressure in rinse 
spray tube  
 
 
 
Low water pressure 
Minimum 25PSI flow pressure 
required 
MODEL GL-C Installation & Operation Manual Rev. 1.00 –2/23/06 
                                                          