LOCATION 
The equipment area must be kept free and clear of combustible substances.   
Minimum Clearances 
 
 
 
Combustible Construction 
Non-Combustible Construction 
 
 
 
Back   
 
2" 
 
 
 
 
0" 
 
Sides   
 
20" 
 
 
 
 
 
Bottom  
 
10" 
 
 
 
 
4" 
 
The  installation  location  must  allow  adequate  clearances  for  servicing  and  proper 
operation.  W hile  another  gas-fired  cheesemelter  can  be  placed  adjacent  to  this 
Cheesemelter, there must be no obstruction to the front  of the Cheesemelter.  A minimum 
front clearance of 36" (91 cm) is required.  
It is recommended that the cheesemelter no t be installed directly over or directly adjacent 
to  charbroilers,  griddles  or  fryer  banks.  Infrared  burners  can  be  susceptible  to  the  effects 
of  grease  laden  smoke  and  installation  in  the se  locations  may  shorten  burner  life.   The 
cheesemelter must be installed so that it is level side to side and front to back.  
Do  not  obstruct  the  flow  of  combustion  and  ventilation  air.  Adequate  clearance  f or  air 
openings into the combustion chamber must be provided.  Make sure there is an adequate 
supply of air in the room to replace air taken out by the ventilating system.  
Do  not  permit  fans  to  blow  directly  at  the  Cheesemelter.  Avoid  wall -type  fans  which 
create  air  cross  currents  within  the  room.   Avoid  open  windows  next  to  the  Cheesemelter.  
Maintain  a  minimum  18"  (46  cm)  clearance  from  the  top  of  the  cheesemelter  flue  vent  to 
the  filters  of  the  hood  venting  system   or  any  other  obstruction .  Maintain  a  minimum  18" 
(46 cm) clearance from the  bottom of the cheesemelter to any other flue discharge area.  
 
INSTALLATION CODES AND STANDARDS  
The Cheesemelter must be installed in accordance with: 
In the United States of America:  
1.  State and local codes. 
2. National Fuel Gas  Code,  ANSI-Z223.1/NFPA  #54 (latest  edition). This shall  include  but 
not  be  limited  to:  NFPA  #54  Section  10.3.5.2  for  Venting.  Copies  may  be  obtained 
from  The  American  Gas  Association  Accredited  Standards  Committee  Z223,    @  400 
N.  Capital  St.  NW , Washington,  DC  20001  or  the  Secretary  Standards  Council,  NFPA, 
1 Batterymarch Park Quincy, MA 02169 -7471  
 
NOTE: In the Commonwealth of Massachusetts  
 
All gas appliances  vented through a ventilation hood or exhaust system equipped  with 
a damper or with a power means of exhaust shall comply with 248 CMR.  
3.  NFPA Standard # 96  Vapor Removal from Cooking Equipment , latest edition, available 
from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.  
In Canada: 
1.  Local codes. 
2.  CAN/CSA-B149.1 Natural Gas Installation (latest edition)    
3.  CAN/CSA-B149.2  Propane  Installation  Code  (latest  edition),  available  from  the 
Canadian Gas Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W  1R3