Справочник Пользователя для Smeg cooktop

Скачать
Страница из 25
 
Instructions for the installer
 
 
 
6.2 Regulation for LPG 
Loosen screw A and push support B all the way. Use a double head 
wrench to remove nozzle C and assemble the suitable one, following the 
instructions indicated in the reference charts, with respect to the type of 
gas to use. The screwing torque of the nozzle should never exceed         
3 Nm. Reposition support B so that nozzle C is covered perfectly. 
Place the burner on its support and ignite it. Move the Venturi tube D to 
regulate the air flow until the flame is stable and burns regularly, then 
secure the tube by means of screw A
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
LPG – 2.75 kPa 
 
 
 
Burner 
Nominal gas 
consumption 
(MJ/h) 
Injector 
(mm) 
Auxiliary (1) 
4.8 
0.60 
Semi rapid (2) 
6.0 
0.68 
Rapid (3) 
9.5 
0.85 
Rapid (4) 
12.5 
0.95 
Wok (5) 
15.0 
1.05 
 
16