Voltage regulators
www.digiembedded.com
13
Receiver 
Sensitivity and 
Transmit Output 
Power
-71 dBm @ 54 Mbps
-81 dBm @ 11 Mbps
-88 dBm @ 6 Mbps
-93 dBm @ 1 Mbps
13.8 dBm OFDM 
17 dBm PSK/CCK
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V o l t a g e   r e g u l a t o r s
The module takes in 3.3V±9% (3.00V to 3.60V) as its main input power. This power is 
filtered and used as a 3.3V supply to portions of the digital logic. This power also 
acts as input to dedicated on-board voltage regulators.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V o l t a g e   m o n i t o r   —   R e s e t   g e n e r a t o r
The module does not provide a voltage monitor or automatic reset signal generator; 
rather, the module uses a reset signal generated by the host system board. 
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
L E D S
The module does not have any on-board LEDs, but it drives the LED_WLAN# signal 
(pin 44) to indicate WLAN association and transmit/receive activity. This table 
shows the different LED states:
LED state
Indication
Off
Not powered on
On
Associated and authenticated
Slow blink
Not associated or authenticated
Intermittent blink
Transmit/receive activity