Справочник Пользователя для Digi 90000797_A

Скачать
Страница из 44
Power requirements
36
Connect Wi-Wave Hardware Reference, Rev A  2/2008
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
P o w e r   r e q u i r e m e n t s  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
R F   e x p o s u r e   s t a t e m e n t
The Digi Connect Wi-Wave module complies with RF exposure limits for humans as 
called out in RSS-102. It is exempt from RF evaluation based on its operating 
frequency of 2.4 GHz, and effective radiated power less than the three watt 
requirement for a mobile device (>20 cm separation) operating at 2.4 GHz.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
S a f e t y   s t a t e m e n t s
To avoid contact with electrical current:
„
Never install electrical wiring during an electrical storm.
„
Use a screwdriver and other tools with insulated handles.
„
Wear safety glasses or goggles.
„
Installation of inside wiring may bring you close to electrical wire, conduit, 
terminals and other electrical facilities. Extreme caution must be used to avoid 
electrical shock from such facilities. Avoid contact with all such facilities.
„
Protectors and grounding wire placed by the service provider must not be 
connected to, removed, or modified by the customer.
„
Do not touch or move the antenna(s) while the unit is transmitting or receiving.
„
Do not hold any component containing a radio such that the antenna is very 
close to or touching any exposed parts of the body, especially the face or eyes, 
while transmitting.
„
Do not operate a portable transmitter near unshielded blasting caps or in an 
explosive environment unless it is a type especially qualified for such use.
Parameter
Limits
Input voltage (Vcc)
3.3V±9% (3.00V to 3.60V)
Input current
750mA max
Input low voltage
0.0V
<V
IL
<0.3*Vcc
Input high voltage
0.7*Vcc
<V
IH
<Vcc
Output low voltage
0.0V
<V
OL
<0.4V
Output high voltage
Vcc-0.4V <V
OH
<Vcc