Testing
November, 2007
79
6740001
TEST THE BREWER
a. Press 
, then press 
 until the display shows 
BREW TEST
.
b. Press 
 to test each brewer position:
WARNING
Keep away from the brewer mechanism while it is operating.  
Coming into contact with moving parts could injure you.
i.
BREW CLMPD
  The brewer is in the brew position.
ii.
BREW HOME
   The brewer is in the HOME position.
c. CONTINUE.
TEST VARIOUS SENSORS AND SWITCHES
a. Press 
, then press 
 until the display shows  
IN.XXXXXX
.  The X's in the 
display will be replaced by the following place holders: 
M K P H L 1
,  defined as follows:
M = mug/cup sensor (if equipped)
K = freevend keyswitch
P = waste pail switch
H = high water tank level switch
L = low water tank level switch
1/2 = ring 1/2 cup sensor switch
b. Actuate each switch or sensor to test its function.  As you actuate each input, the display 
element representing that switch blinks on.  Releasing the switch causes that element to blink 
off again, and be replaced by a dash.
c. CONTINUE.
RINSE ALL MIXING BOWLS
WARNING
Very hot water will be dispensed in this test.  Coming into contact 
with hot water is dangerous!
a. Press 
, then press 
 until the display shows 
BOWL RINSE
.
b. Press 
 to rinse all bowls.  
RINSING
 is displayed.
c. CONTINUE.