Dimensions & Specifications
Bunn-O-Matic Corporation of Canada - 280 Industrial Pkwy. S. Aurora, Ontario  L4G 3T9 • 905-841-2866 • Fax 905-841-2775 • www.bunn.com
CANADA
Model 
Product # 
Volts 
Amps  Tank Htr 
Total 
Capacity 
Cubic   Weight 
Cord 
 
 
 
 
Watts 
Watts 
per hour 
ft
3
/m
3
 
lbs/kg  Attached
CW15-APS*+ 
23001.6001 
120 
12.1 
1450 
1450 
4.2 gal/15.9 liter 
5.1 / .14 
33 / 15.0  
Yes
CW15-APS*++ 
23001.6000 
120 
12.1 
1450 
1450 
4.2 gal/15.9 liter 
5.1 / .14 
33 / 15.0 
Yes
CWT15-APS+ 
23001.6006 
120 
12.1 
1450 
1450 
4.2 gal/15.9 liter 
5.1 / .14 
35 / 15.9 
Yes
 
CWT15-APS++ 
23001.6007 
120 
12.1 
1450 
1450 
4.2 gal/15.9 liter 
5.1 / .14 
35 / 15.9 
Yes
CWTF15-APS+ 
23001.6012 
120 
12.1 
1450 
1450 
4.2 gal/15.9 liter 
5.1 / .14 
38 / 17.2 
Yes
CWTF15-APS++ 
23001.6013 
120 
12.1 
1450 
1450 
4.2 gal/15.9 liter 
5.1 / .14 
38 / 17.2 
Yes
CWTF35-APS+ 
23001.6017  120/208-240  14.6 
3500 
3500 
7.5 gal/28.42 liter 
5.1 / .14 
38 / 17.2 
No
CWTF35-APS++ 
23001.6016  120/208-240  14.6 
3500 
3500 
7.5 gal/28.42 liter 
5.1 / .14 
38 / 17.2 
No 
*Pourover model.     
Power cord (NEMA 5-15P) 15 Amp-120V machine only.  
+ Black trunk and Plastic Funnel.    ++ Stainless Trunk and Plastic Funnel
Brewing capacity: based upon incoming water temp of 60ºF (140ºF rise) per 1/2 gallon brew time of 4 minutes.
Models listed as 120/208V or 120/240V must be connected to 208V or 240V electrical service respectively. Please refer to the installation manual.
Electrical:  CW15-APS,  CWT15-APS & CWTF15-APS - require   2-wires plus ground service rated 120V, single phase, 60Hz. 
 
CWT35-APS & CWTF35-APS - require 3-wires plus ground service rated 120/240V, single phase, 60Hz.
Plumbing:  20-90 psi (138-621 kPa). Supplied with 