AIR SUPPLY AND VENTILATION: Adequate ventilation and air supply 
must be provided in order for the coffee urn to operate properly and 
efficiently. The area in front of and above the unit must be clear to avoid 
any obstruction of flow of combustion and ventilation air. DO NOT under 
any circumstances, connect the coffee urn flue directly to a building 
exhaust system or place the flue outlet directly into the plenum of the 
exhaust hood as it will adversely affect the gas combustion of the coffee 
urn. 
 
CLEARANCES: Your coffee urn is design certified to use on combustible 
floors. The side and back clearances for combustible constructions are as 
follows: 6 inches from side and 8 inches from back. The coffee urn must 
be installed with 4 inch high legs provided. 
 
GAS CONNECTION: Examine the gas specification label attached to the 
urn to be certain that the type of gas for which the unit is equipped is 
the same as the gas supply. A 3/8 NPT gas connection is needed to 
connect the unit to the gas line. An accessible manual shut-off valve 
must be installed in the gas supply line in case of an emergency. The gas 
supply pipe must be sized to accommodate all the gas fired equipment 
that may be connected to it. Check with your local Gas Company as to 
proper pipe size. Sealant on all pipe joints must be resistive to propane 
gas. Before attempting to light the coffee urn, check all joints for gas 
tightness using a soap and water solution. 
 
WATER CONNECTION: Unit is supplied with a water strainer and a 19” 
length of ¼” copper tubing with a flare fitting. Connect the copper tubing 
with the flare fitting to the water connection at the rear of the machine. 
The other end of the strainer is connected with a suitable length of ¼” 
tubing and a shut-off valve (supplied by a plumber) to a cold water 
supply. Water pressure should be minimum of 20 lbs. for proper 
operation.  
 
To turn on the water supply valve plug the line cord into a 120 V 
grounded outlet. The water will start entering the unit and automatically 
fill it to capacity.   
 
LIGHTING AND ADJUSTMENT: Water must be visible in the sight glass 
before lighting to pilot. Turn the thermostat knob to its lowest position. 
Turn gas cock dial to PILOT position. Depress gas cock dial and light pilot 
with a long lighted match through the opening located on the bottom of 
the urn. Hold in depressed position for approximately 30 sec. or until 
pilot remains lit when dial is released.   
NOTE: On the first lighting it may be necessary to hold the dial for a 
longer period to allow trapped air to escape from the line. 
 
DIAL SETTINGS AND CORRESPONDING WATER TEMPERATURES: 
“1”= 50F, “10”=198F