Справочник Пользователя для Vulcan-Hart GRD65 ML-052082

Скачать
Страница из 36
– 18 –
PARAMETER
SELECT
DISPLAY
SCROLL
Left Timer
Press        or        to  enter time.
LED is lit above the left basket
icon. The time value is displayed
in window.
Press       and
scroll to next
item.
Right Timer
Press        or        to  enter time.
LED is lit above the right basket
icon. The time value is displayed
in window.
Press       and
scroll to next
item.
Set Temperature
Press        or        to  enter
temperature.
The temperature value is
displayed in window.
Press       and
scroll to next
item.
Offset
Calibration
For service only
00F
or
-00F
Press       and
scroll to next
item.
Melt Options:
Liquid shortening
Solid shortening
No melt
Press        or        to select melt
option.
CY L (Liquid shortening)
or
CY S (Solid shortening)
or
CY O (No melt)
Press       and
scroll to next
item.
Energy
Source
Press        or        to select
source of heat.
gAS
or
ELEC
Press       and
scroll to next
item.
Parameter Lock
Press        or        to  lock or
unlock program entry.
LoC (Unlock Parameter)
or
ULoC (Lock Parameter )
Press       and
scroll to next
item.
Fahrenheit or
Celsius
Press        or        to
select Fahrenheit or Celsius.
F
or
C
Press       and
scroll to next
item.
PROGRAMMING
Temperature, time and other parameters must be set before operating. Once these parameters are set,
the fryer can be operated at the touch of a button.
Press  
  to enter the program mode and scroll through the parameters. If the Parameter Lock feature
is on, LoC is displayed in the window and program entry cannot be accessed. To access the program
mode while LoC is on, press 
  
  
  
  within 6 seconds of pressing 
 . To turn the
Parameter Lock feature off, see Program Guide below.
Programming Guide
 Once in the program mode, the parameters are displayed in the order listed below. To exit the program
and save changes, press and  hold  
  for approximately 2 seconds.