GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS 
VULCAN-HART                                                                                                                F-32934 Rev. J (August 2012) 
-26-
 
 
MAINTENANCE 
  
 
    Hot oil and hot parts can cause burns. Use care when operating, 
                          cleaning, and servicing the fryer. 
 
 
 
 
 
    Spilling hot fryer compound can cause severe burns.  Do not  
 
               move fryer without draining all frying compound from the tank.          
 
FLUE VENT INSPECTION 
 
When the fryer is cool, inspect annually.  Check the flue and clear any obstructions. 
 
 
Service in the US and Canada 
 
Contact you local Vulcan-Hart Service office or address on the front of this manual. 
 
In Australia 
 
Contact Hobart Food Equipment PTY. LTD., 16 Hilly Street Morlake, N.S.W. 2137 Australia; 
P.O. Box 100, Concord N.S.W. 2137; Tel: (02) 9736 1200; Fax: (02) 9736 1555.  
www.hobartfood.com.au
 
 
 
Troubleshooting Chart: 
 
Problem: 
    Probable 
Cause: 
 
No Heat: 
 
 
 
 
Power switch not turned on. 
      Gas 
supply 
not 
turned 
on. 
 
      Wire 
connections 
loose 
(call 
service) 
      Wires 
connections 
need 
cleaning 
      High 
Limit 
(call 
service) 
 
Insufficient or too much heat: 
 
 
Temperature not set to desired temperature. 
      High 
limit 
tripped 
(call 
service) 
      Temperature 
probe 
(call 
service) 
 
 
 
 
 
 
 
Tank will not drain: 
 
 
 
Shortening too cold. 
      Drain 
pipe 
clogged 
with 
debris. 
 
Motor / pump will not pump oil:   
 
Suction tube not seated correctly in receptacle block. 
      Filter 
screen 
is 
clogged 
and 
needs 
cleaning. 
      Shortening 
is 
too 
thick 
cold.  Heat oil up to min. 300º F. 
      Discard 
valve 
lever 
not 
fully engaged either for filtering or
 
 
 
 
 
 
 
discarding.