FRYER BOIL-OUT INSTRUCTIONS
CAUTION:  Do not run water or boil-out solution through the filter motor or pump.  Do not use
the filter during boil-out or cleaning of the fryer.
Before cleaning the fryer, read the entire cleaning instructions provided by the cleaning product's
manufacturer.  Some cleaners will require a boil-out procedure at boiling temperature, and some will
not.  If your cleaning product company calls for a boil-out procedure, follow their procedures after
performing steps 1 through 5. If boil-out is required, but no procedures are stated, follow steps 1 through
23.
1. Turn off the fryer that is to be boiled out.
2. Remove and set aside the filter drawer assembly.
3. Drain all shortening from the fryer to be boiled out. Drain old
shortening into a suitable disposal container and discard.
4. Remove the filter screen assembly from the filter drawer vessel and
separate the screen into two parts (see page 10).
5. Place the two separated parts of the screen assembly into the fryer
tank that is to be boiled out.
6. Following the cleaning instructions on page 10, clean the remaining drawer assembly parts.
7. Place a stock pot under the drain manifold opening (Fig. 20).
8. Close the drain valve and fill the fryer tank with hot water to the - Max - fill line.
9. Set the fryer thermostat to 210°F to 225°F (99°C to 107°C) and turn the fryer on.
10. Allow water to simmer.
11. Add boil-out solution and mix thoroughly.  Do not boil solution.  This may cause the fryer to boil
over.  Simmer water to dissolve solution completely and achieve the maximum cleaning benefit.
12. Allow the fryer to simmer for 10 to 15 minutes.  Watch the fryer to make sure it does not boil over.
During the boil-out process, scrub the tank using the cleaning brush provided with the fryer.  To
avoid damage to the tank finish, do not use a metal brush or scouring pad.
13. Turn the fryer off and allow the boil-out solution to remain in the fry tank for another 10 to 15
minutes.  The hot boil-out solution will continue to break down oil residue at water temperatures
as low as 180°F (82°C).
14. Open the drain valve.
15. Drain the boil-out compound into the stock pot below the drain
manifold opening (Fig. 21).  Monitor the contents of the stock pot.
The full content of the fryer tank may not fit into the stock pot.  If not,
close the drain valve when the stock pot is almost full and discard
the boil-out solution.
16. Replace the emptied stock pot below the drain manifold opening,
and repeat steps 14 and 15 as many times as needed.
17. Close the drain valve and fill the tank with clean, hot water to the - Max - fill line; drain and discard
as in steps 14 and 15.
Fig. 20
PL-41623
PL-41625
Fig. 21