GBD_GBDF SERIES GAS FRYERS 
VULCAN-HART                                                                                                               F-32934 Rev. B (June 2008) 
-6-
 
 
Clearances: 
 
Š 
Minimum clearance from combustible construction: 
 
6” (15 cm) from the sides of the fryer 
6” (15 cm) from the back of the fryer 
The fryer may be installed on combustible floors. 
 
Š 
Minimum clearance from noncombustible construction: 
 
0” from the sides of the fryer 
0” from the back of the fryer 
 
Š 
Between the fryer and any open-top flame units: 
 
16” (41 cm) 
 
Š 
Allow space for servicing and operation. 
 
Location: 
 
Š 
Install fryer in an area with sufficient air supply for gas combustion at fryer 
 burners. 
 
Š 
Do not obstruct the flow of combustion and ventilation air. 
 
Š 
Provide adequate clearance for air openings into the combustion chamber. 
 
Š 
Do not permit fans to blow directly onto fryer. 
 
Š 
Avoid wall-type fans, which create cross-currents within a room.  Avoid 
 open windows next to sides or back. 
 
CODES AND STANDARDS 
 
The fryer must be installed in accordance with: 
 
In the United States: 
 
Š 
State and local codes, or in the absence of local codes, with: 
 
Š 
National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition).  Copies may 
 be obtained from The American Gas Association Accredited Standards 
Committee Z223, @ 400 N. Capital St. NW, Washington, DC 20001 or the 
Secretary Standards Council, NFPA, 1 Batterymarch Park Quincy, MA 02169-
7471. 
 
Š 
NFPA Standard #96 Vapor Removal from Cooking Equipment, latest edition,  
available from the National Fire Protection Association, Batterymarch Park, 
Quincy, MA. 02169-7471.