Справочник Пользователя для Vulcan-Hart 1GR45M

Скачать
Страница из 24
GRM SERIES GAS FRYERS 
VULCAN-HART                                                                                                               F-31233 Rev. F (January 2008) 
-7-
 
 
Š 
CAN/CSA-B149.2 Propane Installation Code (latest edition), available from the 
 Canadian Gas Association 178 Rexdale Blvd., Etobicoke, Ontario Canada 
M9W 1R3. 
ASSEMBLY 
 
The fryer must be restrained to prevent tipping and the splashing of hot liquid.  The means 
of restraint may be the manner of installation, such as connection to a battery of 
appliances, installing the fryer in an alcove, or by separate means such as adequate ties. 
 
FLUE CONNECTION 
 
Make the flue connection as follows: 
 
Š 
Comply with Vapor Removal from Cooking Equipment, ANSI-NFPA 
Standard #96 (latest edition), available from the National Fire Protection 
Association, Batterymarch Park, Quincy, MA  02269. 
 
Š 
Locate the fryer under a hood with adequate connection to an exhaust 
duct.  The hood must extend 6” (15 cm) beyond fryer on both sides. 
 
Š 
Clearance above the fryer should be adequate for combustion byproducts  
to be removed efficiently. 
 
Š 
An 18” (46 cm) minimum clearance should be maintained between the flue 
 vent and the filters of the hood venting system. 
 
Š 
Never make flue connections directly to the fryer. 
 
Š 
Do not obstruct the flow of the gases from the appliance.  Proper air  
balance should be maintained in the room. 
 
GAS CONNECTION 
 
  
         All gas supply connections and any pipe joint compound must be  
      
         resistant to the action of propane gases. 
 
The gas inlet is located on the lower rear of the fryer.  Codes require that a gas shutoff 
valve be installed in the gas line ahead of the fryer. 
 
The gas supply line must be at least the equivalent of ½” (12.7 mm) iron pipe for single 
units and 1-1/4” (31.75 mm) for batteries.  If using the optional quick-disconnect flex hose, 
¾” (19 mm) iron pipe for single units and 1-1/4” (31.75 cm) iron pipe for batteries. 
 
Make sure the pipes are clean and free of obstructions, dirt, and piping compound.  A 
battery requires one or two connections of appropriate size for the gas requirement.