Справочник Пользователя для U-Line U-3060RFOL-00

Скачать
Страница из 21
6
u-line.com
3045/3060 Model
1. To begin, press U-Select Lighting 
 to enter the lighting menu.
2. Use Up 
 or Down 
 to cycle through each available brightness 
setting; Low, Medium, or High.
3. Use U-Select Lighting 
 to cycle through each available timer 
setting. Selections include “On With Door”, “On 3 Hours”, “On 6 
Hours”, or “On 24 Hours”.
4. To exit, press Select 
 or simply wait for the menu to time out.
Error Notification
The 3000 model series continuously monitors a series of inputs and 
parameters to ensure proper and efficient operation of your unit. 
Should the system detect a fault, an error notification will be displayed 
on the user interface. See below for a list of errors
Note: Singe zone models will not use (L) left or (R) right zone 
indicators in error notification.
Customer Menu
The 3000 Series of U-Line undercounter refrigeration appliances 
contain a feature rich customer menu. The Customer Menu allows 
access to a Series of advanced features including Energy Saver Mode, 
Sabbath mode, actual temperature readings as well a method to 
restore factory defaults. 
3000 Series - Customer Menu
1. To access the Customer Menu hold Select 
 for 5 seconds.
2. Use Up 
 or Down 
 to scroll through available selections.
3. Use Select 
 to enter selected sub-menu.
4. To exit Customer menu, Use Down 
 to scroll to the bottom of 
the display and use Select 
 to Select “Exit.”
Actual Temps
The Actual Temps option displays the actual temperature of each zone, 
evaporator, as well as climate range. 
1. To view actual temperature, Select 
 Actual Temps from the 
customer menu.
2. Use Up 
 or Down 
 to scroll through available information.
3. To return to the customer menu, Select 
 Return to Menu.
Energy Saver Mode
Energy Saver mode reduces overall energy consumption by altering 
user set point, differential, lighting and tone settings. When in Energy 
Saver mode a small leaf icon will be displayed on the main screen.
1. To enter Energy Saver first select Energy Saver from the 
Customer Menu.
2. Use Down 
 to select “Off” in the menu. 
ID
Description
Solution
No Comm
Unit lost 
communication to the 
display.
Disconnect and reconnect 
power to unit. Contact 
customer care if 
persistent.
(L) (R) Zone T 
Open
Left or right zone 
thermistor circuit 
open.
Contact Customer Care.
Amb Thrm Open
Ambient thermistor 
circuit open.
Contact Customer Care.
(L) (R) Zone T 
Short
Left or right zone 
thermistor circuit 
shorted.
Contact Customer Care.
Amb Thrm Short
Ambient thermistor 
circuit shorted.
Contact Customer Care.
(L) (R) Temp Hi 
6H+
Left or right Zone 
temperature +10° 
over set point for over 
6 hours.
Verify door is closed and 
sealing. Contact customer 
care if persistent.
(L) (R) Temp Hi 
12H+
Zone temperature 
+10° over set point for 
over 12 hours.
Verify door is closed and 
sealing. Contact customer 
care if persistent.
(L) (R) Temp Lo 
6H+
Zone temperature
-10° under set point 
for over 6 hours.
Verify door is closed and 
sealing. Contact customer 
care if persistent.
(L) (R) Temp Lo 
12H+
Zone temperature
-10° under set point 
for over 12 hours.
Verify door is closed and 
sealing. Contact customer 
care if persistent.
(L) (R) Door 
Open 5M
Door switch open for 
more then 5 minutes.
Verify door is closed and 
sealing. Contact customer 
care if persistent.
Up
Select
Down
U-Select Lighting
Power
Up
Select
Down
WELCOME TO THE
CUSTOMER MENU. USE
UP/DOWN ARROWS TO
SCROLL SETTINGS.
Up
Select
Down
RETURN TO MENU
ACTUAL TEMPS
BIN TEMP = 2°C
COND TEMP = 46°C
    
Up
Select
Down
Energy Saver Mode
Indicator
ICE PRODUCTION
(12m remaining)