Справочник Пользователя для Liebherr LGex 910

Скачать
Страница из 11
21
GB
Installation dimensions 
(mm)
 LGUex 1500
Version 1
A cross-section of min. 200 cm
2
 is re quired in the 
worktop for ventilation of the rear of the appliance. 
Version 2
If no ventilation grille is provided in the worktop, the recess 
must be at least 860 mm high to ensure adequate heat 
dissipation to the front.
1.
  Unscrew the hinge bracket.
Important: The door mounting has 
a spring mechanism enabling the 
door  to  close  by  itself.  The  hinge 
bracket turns to the left when the 
screws are undone.
2. 
Pull the door out at the bottom 
and lift off.
3.
  Transfer handle and plugs to the 
opposite side of the door.
4.
  Transfer pin on hinge bracket to the 
opposite side.
5.
  Transfer upper hinge components to 
the opposite side.
6.
  Transfer cover plate to the opposite 
side.
7.
  Mount door on hinge pin and close.
8.
  Insert hinge bracket in lower door 
mounting.
9.
  Turn hinge bracket by 90° - spring 
is  compressed.  Screw  on  hinge 
bracket.
Changing over door hinges
Veiligheidsslot
Het slot in de deur van het apparaat 
is met een veiligheidsmechanisme 
uitgerust. 
Apparaat afsluiten:
•  Sleutel in de richting 1 naar binnen 
duwen.
•  Sleutel 90° draaien.
Om het apparaat weer te ontgren-
delen moet in dezelfde volgorde te 
werk worden gegaan.