Справочник Пользователя для Henny Penny EEE-142

Скачать
Страница из 63
Model EEE-141,142, 143, 144
7-2.    ERROR CODES
In the event of a control system failure, the digital display shows an
error message.  The message codes are shown in the DISPLAY
column below.  A constant tone is heard when an error code is
displayed, and to silence this tone, press any button.
DISPLAY
CAUSE
CORRECTION
“E-4”
Control board
Turn switch to OFF position, then turn switch back to ON;
overheating
if display shows “E-4”, the control board is getting too hot;
check the louvers on each side of the unit for obstructions
“E-5”
Oil
Turn switch to OFF position, then turn switch back to ON;
overheating
if display shows “E-5”, the heating circuits and temperature
probes should be checked
“E-6A”
Temperature
Turn switch to OFF position, then turn switch back to ON;
probe open
if display shows “E-6A”, the temperature probe should be
checked
“E-6B”
Temperature
Turn switch to OFF position, then turn switch back to ON;
probe shorted
if display shows “E-6B”, the temperature probe should be
checked
“E-10”
High limit
Reset the high limit by using a small screwdriver or Allen
wrench gently pushing it into the hole in the heating element
hinge; if high limit does not reset, high limit may need be replaced
“E-15”
Drain switch
Make sure drain knob is completely pushed-in; if E-15 persists,
have drain switch checked
“E-18-A”
Left level sensor open
Turn switch to OFF position, then turn switch back to ON;
“E-18-B”
Right level sensor open
if display still indicates a failed sensor, have the connectors checked
“E-18-C”
Both level sensors open at the control board; have sensor checked & replace if necessory
209
       7-3