Calibrate HLZ 
Semi-annual 
PR 10 S1 
 
 
©McDonald’s Corporation · Planned Maintenance Manual · Revised July 2007 
Page 1 of 1
 
Frymaster Heated Landing Zone (HLZ) Models HLZ
18, HLZ22 
Semi-annual 
PR 10 S1
 
Why 
To ensure correct holding temperature and accuracy of computer controls 
Time required 
20 minutes to prepare 
10 minutes to complete 
Time of day 
During low-volume times 
For 24-hour restaurants: During low-volume times 
Hazard icons 
  
Tools and supplies 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Pyrometer with dual 
male connectors 
 
 
 
 
 
 
 
 
 
 
 
 
Procedure
Make sure HLZ is clean and at 
proper operating temperature. 
Make sure the HLZ is clean 
and has been turned on for at 
least 20 minutes. The display 
should read “REdY”. 
 
Plug pyrometer connector into 
“AIR” receptacle on HLZ. 
 
 
The HLZ is hot. 
 
Read and compare air 
temperatures. 
Wait 3 minutes for the py-
rometer readout to stabilize.  
 
Press the heater temperature 
switch once to display the 
HLZ air temperature readout. 
 
Compare the two temperature 
readings. If the two tempera-
tures are more than 15°F 
(9°C) apart, contact your  
Factory-Authorized Service 
Center. 
 
Plug pyrometer connector into 
“PLATE” receptacle on HLZ. 
 
 
Read and compare plate 
temperatures.  
Wait 3 minutes for the py-
rometer readout to stabilize.  
 
Press the heater temperature 
switch once to display the 
HLZ plate temperature read-
out. 
 
Compare the two temperature 
readings. If the two tempera-
tures are more than 10°F 
(5°C) apart, contact your  
Factory-Authorized Service 
Center.