OVERVIEW
FRONT VIEW
1.   Remote sensor reception indicator
2.   Outdoor temperature
3.   Indoor temperature
4.   Ice alert LED indicator
BACK VIEW 
1.   °C / °F: Select temperature unit
2.   RESET: Reset unit to default settings
REMOTE SENSOR  
1.   LED status indicator
2.   Wall mount hole
3.   Battery compartment 
4.   RESET hole 
5.   CHANNEL switch
GETTING STARTED
INSERT BATTERIES
1.   Remove the battery compartment.
2.   Insert the batteries, matching the polarities (see 
FIG 2).
3.   Press RESET after each battery change.
Wireless Indoor and 
Outdoor Thermometer 
with LED Ice Alert
Model: EMR201
USER MANUAL
4
2
3
1
T E M P
T E M P
IN
OUT
���������
RESET
C/ F
2
1
REMOTE SENSOR 
To set up the sensor:
1.   Open the battery compartment (see FIG 3).
2.   Select channel 1 then press RESET
3.   Close the battery door.
4.   Place the sensor within 30 m (98 ft) of the main 
unit using the table stand or wall mount.
TIP Ideal placements for the sensor would be in any 
location on the exterior of the home at a height of 
not more than 5 ft and which can shield it from direct 
sunlight or wet conditions for an accurate reading. 
NOTE Use alkaline batteries for longer usage and 
consumer  grade  lithium  batteries  in  temperatures 
below freezing.
SENSOR DATA TRANSMISSION
To search for a sensor: 
Reset the unit.
The sensor reception icon in the remote sensor area 
shows the status:
TIP  The  transmission  range  may  vary  depending 
on many factors. You may need to experiment with 
various locations to get the best results.
ICE WARNING
If the channel 1 sensor falls between 3°C to -2 °C 
(37°F to 28°F), LED indicator will flash, and will stop 
flashing once the temperature is out of this range. 
RESET
Press RESET to return to the default settings.
PRECAUTIONS
•   Do  not  subject  the  unit  to  excessive  force, 
shock, dust, temperature or humidity.
•   Do not cover the ventilation holes with any items 
such as newspapers, curtains etc.
•   Do  not  immerse  the  unit  in  water.  If  you  spill 
 
liquid  over  it,  dry  it  immediately  with  a  soft, 
 
lint-free cloth.
•   Do not clean the unit with abrasive or corrosive 
materials. 
•   Do  not  tamper  with  the  unit’s  internal 
 
components. This invalidates the warranty.
•   Only  use  fresh  batteries.  Do  not  mix  new  and 
old batteries.
•   Images  shown  in  this  manual  may  differ  from 
the actual display.
•   When  disposing  of  this  product,  ensure  it  is 
 
collected separately for special treatment.
  
 LOCATION  
    MEANING
Indoor temperature 
area
Outdoor temperature 
area
Main unit batteries low
Sensor batteries low
  ICON  
                      DESCRIPTION
Main unit is searching 
for sensor(s).
A channel has been 
found.
The sensor cannot be 
found.
OUT
OUT
OUT
OUT
OUT
OUT
OUT
•   Placement  of  this  product  on  certain  types 
of  wood  may  result  in  damage  to  its  finish  for 
which Oregon Scientific will not be responsible. 
 
Consult  the  furniture  manufacturer’s  care 
 
instructions for information.
•   The  contents  of  this  manual  may  not  be 
 
reproduced  without  the  permission  of  the 
 
manufacturer.
•   Do  not  dispose  old  batteries  as  unsorted 
 
municipal  waste.  Collection  of  such  waste 
 
separately for special treatment is necessary.
•   Please note that some units are equipped with 
a battery safety strip. Remove the strip from the 
battery compartment before first use.
NOTE The technical specifications for this product 
and the contents of the user manual are subject to 
change without notice.
SPECIFICATIONS 
ABOUT OREGON SCIENTIFIC 
Visit  our  website  (www.oregonscientific.com)  to 
learn  more  about  Oregon  Scientific  products.  If 
you’re  in  the  US  and  would  like  to  contact  our 
Customer  Care  department  directly,  please  visit: 
www2.oregonscientific.com/service/support 
OR 
Call 1-800-853-8883. 
For international inquiries, please visit: 
www2.oregonscientific.com/about/international
FCC STATEMENT  
This device complies with Part 15 of the FCC Rules. 
Operation is subject to the following two conditions: 
(1) This device may not cause harmful interference, 
and  (2)  This  device  must  accept  any  interference 
received,  including  interference  that  may  cause 
undesired operation.
WARNING Changes or modifications not expressly 
approved  by  the  party  responsible  for  compliance 
could  void  the  user’s  authority  to  operate  the 
equipment.
NOTE This equipment has been tested and found 
to  comply  with  the  limits  for  a  Class  B  digital 
device, pursuant to Part 15 of the FCC Rules. These 
limits are designed to provide reasonable protection 
against  harmful  interference  in  a  residential 
installation.
This  equipment  generates,  uses  and  can  radiate 
radio  frequency  energy  and,  if  not  installed  and 
used in accordance with the instructions, may cause 
harmful  interference  to  radio  communications. 
However,  there  is  no  guarantee  that  interference 
will  not  occur  in  a  particular  installation.  If  this 
equipment does cause harmful interference to radio or 
television  reception,  which  can  be  determined 
by  turning  the  equipment  off  and  on,  the  user  is 
encouraged to try to correct the interference by one 
or more of the following measures:
 TYPE 
                 DESCRIPTION
MAIN UNIT
L x W x H
241 g (8.5 oz) without battery
66 x 27.5 x 87.5 mm
(2.59 x 1.08 x 3.44 in) 
Weight
Temperature range -5°C to 50°C (23°F to 122°F)
Resolution
0.1°C (0.2°F)
Signal frequency 
433 MHz
Humidity range
25% - 95%
Humidity resolution 1%
Power
2 x UM-4 (AAA) 
1.5 V batteries
REMOTE UNIT (THN132N)
L x W x H
96 x 50 x 22 mm 
(3.78 x 1.97 x 0.87 in)
Weight
62 g (2.22 ounces)
Transmission range 30 m (98 ft) unobstructed
Temperature range -20°C to 60°C (-4°F to 140°F)
Power
1 x UM-3 (AA) 1.5 V batteries
·   Reorient or relocate the receiving antenna.
·   Increase the separation between the equipment 
and receiver.
·   Connect the equipment into an outlet on a circuit 
  different  from  that  to  which  the  receiver  is 
  connected.
·   Consult the dealer or an experienced radio / TV 
technician for help.
DECLARATION OF CONFORMITY
The  following  information  is  not  to  be  used  as 
contact  for  support  or  sales.  Please  call  our 
customer service number (listed on our website at 
www.oregonscientific.com, or on the warranty card 
for this product) for all inquiries instead.
We
Name: 
 
Oregon Scientific, Inc.
Address:   
19861 SW 95th Ave.,Tualatin,
 
 
Oregon 97062 USA
Telephone No.: 
1-800-853-8883
declare that the product 
Product No.: 
EMR201
Product Name: 
Wireless Indoor and Outdoor  
 
 
Thermometer with LED Ice  
 
 
Alert
Manufacturer: 
IDT Technology Limited
Address:   
Block C, 9/F, Kaiser Estate,
 
      
Phase 1,41 Man Yue St.,     
 
 
Hung Hom, Kowloon, 
 
 
Hong Kong
is  in  conformity  with  Part  15  of  the  FCC  Rules.  
Operation is subject to the following two conditions: 
1) This device may not cause harmful interference.
2)  This  device  must  accept  any  interference 
received,  including  interference  that  may  cause 
undesired operation.
© 2007 Oregon Scientific. All rights reserved.
P/N: 086L005000-011
2
3
4
5
1