Справочник Пользователя для Vulcan-Hart GL40E ML-52635

Скачать
Страница из 12
– 12 –
MAINTENANCE
WARNING
:  THE KETTLE AND ITS PARTS ARE HOT.  USE CARE WHEN OPERATING,
CLEANING AND SERVICING THE KETTLE.
WARNING
:  DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW
LOCKOUT / TAGOUT PROCEDURE.
PRESSURE RELIEF VALVE
Open the pressure relief valve at least once a day to avoid lime build-up.  If leakage occurs or
if the valve opens below the rated psi, it will need to be replaced by your Vulcan authorized
servicer.
LOW WATER CUT-OFF
This device should be removed and inspected for lime build-up at least once a year.  The float
must move freely in its cage.  Clean if necessary.  Replace if lime or sludge cannot be removed
to allow the float to move freely.  Contact your local Vulcan authorized servicer.
JACKET WATER & JACKET WATER TREATMENT
The kettle jacket is filled at the factory with chemically pure water mixed with a boiler treatment
corrosion inhibitor.  During normal kettle operation, it should not be necessary to frequently add
water to the kettle jacket.  If the water level in the sight glass falls below half, add distilled or
chemically pure water to the jacket through the fill tube.  The water level in the sight glass should
be maintained to just above the halfway position in the sight glass.
If the water in the sight glass appears dirty, it is necessary to have a qualified service technician
remove the fluid in the kettle, perform a delime or cleaning operation and refill the kettle with
distilled, chemically pure water with a boiler treatment additive.
Do not fill kettle jacket with chlorinated tap water.  Appliance failure caused by water quality is
not covered under warranty.
HOOD VENTILATION SYSTEM
Annually, when cool, check the ventilation system and clear any obstructions.
SERVICE AND PARTS INFORMATION
To obtain service and parts information concerning the kettle, contact the Vulcan-Hart Service
Agency in your area (refer to listing supplied with the kettle), or Vulcan-Hart Company Service
Department at the address or phone number shown on the front cover of this manual.
FORM 30960 Rev. B (Oct. 2003)
PRINTED IN U.S.A.